文献速递外周血管泌尿生殖腹部MRDSA

非对比增强磁共振血管成像:评估移植肾动脉狭窄的可靠临床工具

Non-contrast-enhanced magnetic resonance angiography: a reliable clinical tool for evaluating transplant renal artery stenosis.
PubMed 文献 · Eur Radiol · 2018-04-17

纳入2014年7月至2017年6月接受369次非对比增强MRA检查的330例患者,评估图像质量并与DSA对照。95.4%(352/369)检查图像质量良好或优秀,观察者间一致性良好(K=0.760);在有DSA对照的22例患者28次MRA中,非对比增强MRA正确检出19例移植肾动脉狭窄和9条正常动脉,按血管计算准确率96.6%。

要点

  • 非对比增强MRA图像质量良好或优秀者占95.4%(352/369),观察者间一致性K=0.760。
  • 非对比增强MRA可清晰显示移植肾动脉解剖,并与DSA在移植肾动脉狭窄上相关性良好。
  • 有DSA对照的28次MRA中,非对比增强MRA正确检出19例移植肾动脉狭窄和9条正常动脉,按血管计算准确率96.6%。

核心结论

  • 非对比增强MRA能良好显示移植肾动脉,在移植肾动脉狭窄病例中与DSA相关性良好。

研究设计与样本

  • 研究纳入2014年7月至2017年6月接受369次非对比增强MRA检查的330例患者,其中30例至少接受两次MRA检查;由两名放射科医生独立评估图像质量并分析观察者间一致性,将移植肾动脉解剖及并发症与DSA对照,在可能时按血管计算准确率。

关键影像表现/征象

  • 95.4%(352/369)的检查图像质量良好或优秀,观察者间一致性良好(K=0.760)。
  • 22例有DSA对照的患者在2个月内接受了28次非对比增强MRA检查。
  • 上述22例中,19例为移植肾动脉狭窄,2例为假性动脉瘤,1例移植肾动脉正常但髂外动脉闭塞。
  • 非对比增强MRA正确检出19例移植肾动脉狭窄和9条正常动脉,按血管计算准确率96.6%。

诊断标准与关键数值

  • 以DSA为金标准,非对比增强MRA按血管计算准确率为96.6%。

临床应用与阅片要点

  • 非对比增强MRA可清晰显示移植肾动脉解剖,并可用于检出移植肾动脉狭窄。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate image quality of non-contrast-enhanced magnetic resonance angiography (MRA) and compare transplant renal artery stenosis (TRAS) seen by non-contrast-enhanced MRA with digital subtraction angiography (DSA) as the gold standard.

MATERIALS AND METHODS: 330 patients receiving 369 non-contrast-enhanced MRA examinations from July 2014 to June 2017 were included. Thirty patients received at least two MRA examinations. Image quality was independently assessed by two radiologists. Inter-observer agreement was analyzed. Transplant renal artery anatomy and complications were evaluated and compared with DSA. If possible, accuracy was calculated on a per-artery basis.

RESULTS: Good or excellent image quality was found in 95.4 % (352/369) of examinations with good inter-observer agreement (K=0.760). Twenty-two patients with DSA had 28 non-contrast-enhanced MRA examinations within a 2-month period. Of these, 19 patients had TRAS, two patients had pseudoaneurysms, and one patient had a normal transplant renal artery but an occluded external iliac artery. Non-contrast-enhanced MRA correctly detected 19 TRAS and nine normal arteries, giving 96.6 % accuracy on a per-artery basis.

CONCLUSIONS: Non-contrast-enhanced MRA demonstrates a good depiction of the transplanted renal artery and shows good correlation with DSA in cases where there was TRAS.

KEY POINTS: • Good or excellent image quality was found in 95.4 % of examinations. • Non-contrast-enhanced MRA can clearly map transplant renal artery anatomy. • Non-contrast-enhanced MRA is a reliable tool to detect TRAS.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang LJ, Peng J, Wen J, et al. Non-contrast-enhanced magnetic resonance angiography: a reliable clinical tool for evaluating transplant renal artery stenosis. Eur Radiol. 2018. PMID: 29666993. doi:10.1007/s00330-018-5413-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。