文献速递腹部MR

基于IVIM模型的精准肝脏病灶表征仅需三个b值DWI即可实现

Accurate IVIM model-based liver lesion characterisation can be achieved with only three b-value DWI.
PubMed 文献 · Eur Radiol · 2018-04-18

本研究回顾性分析173个肝脏病灶和40个健康肝脏在1.5T下呼吸门控DWI(b=0、50、250、800 s/mm2)数据,计算简化IVIM参数。结果显示f1'鉴别局灶性结节增生AUC达0.989,D1'鉴别血管瘤AUC达0.994,ADC(0,800)和D1'鉴别良恶性病灶AUC分别为0.915和0.858,D1'联合f1'可进一步提高鉴别力。结论认为三个b值(0、50、800 s/mm2)的简化IVIM分析优于两b值ADC,且优于b=0、250、800 s/mm2组合,第四个b值无额外获益。

要点

  • 简化IVIM参数D1'和f1'对肝脏病灶鉴别力优于常规ADC。
  • b=0、50、800 s/mm2组合优于b=0、250、800 s/mm2组合。
  • 采集第四个b值对病灶鉴别诊断无进一步获益。

核心结论

  • 从三个b值近似得到的IVIM参数D和f在肝脏病灶间的鉴别力优于两b值ADC。
  • b=0、50、800 s/mm2组合优于b=0、250、800 s/mm2组合。
  • 采集四个而非三个b值对病灶表征无进一步获益。

研究设计与样本

  • 回顾性分析呼吸门控MRI序列DWI数据,b值包括0、50、250、800 s/mm2,场强1.5T。
  • 纳入173个病灶和40个健康肝脏。
  • 体素级计算ADC(0,800)、D1'=ADC(50,800)、D2'=ADC(250,800)、f1'、f2'、D*'、ADClow=ADC(0,50)和ADCdiff=ADClow-D2',未使用拟合程序。

诊断标准与关键数值

  • f1'鉴别局灶性结节增生与所有其他病灶的AUC为0.989。
  • D1'鉴别血管瘤的AUC为0.994。
  • ADC(0,800)和D1'鉴别恶性与良性病灶的AUC分别为0.915和0.858。
  • D1'联合f1'可进一步提高鉴别力。

临床应用与阅片要点

  • 采用b=0、50、800 s/mm2三个b值即可获得简化的IVIM参数用于肝脏病灶表征。
  • 简化IVIM分析可保证体素级结果数值稳定且采集时间短。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The objective of this study was to evaluate a simplified intravoxel incoherent motion (IVIM) approach of diffusion-weighted imaging (DWI) with four b-values for liver lesion characterisation at 1.5 T.

METHODS: DWI data from a respiratory-gated MRI sequence with b = 0, 50, 250, 800 s/mm2 were retrospectively analysed in 173 lesions and 40 healthy livers. The apparent diffusion coefficient ADC = ADC(0,800) and IVIM-based parameters D1' = ADC(50,800), D2' =ADC(250,800), f1', f2', D*', ADClow = ADC(0,50), and ADCdiff=ADClow-D2' were calculated voxel-wise without fitting procedures. Differences between lesion groups were investigated.

RESULTS: Focal nodular hyperplasias were best discriminated from all other lesions by f1' with an area under the curve (AUC) of 0.989. Haemangiomas were best discriminated by D1' (AUC of 0.994). For discrimination between malignant and benign lesions, ADC(0,800) and D1' were best suited (AUC of 0.915 and 0.858, respectively). Discriminatory power was further increased by using a combination of D1' and f1'.

CONCLUSION: IVIM parameters D and f approximated from three b-values provided more discriminatory power between liver lesions than ADC determined from two b-values. The use of b = 0, 50, 800 s/mm2 was superior to that of b = 0, 250, 800 s/mm2. The acquisition of four instead of three b-values has no further benefit for lesion characterisation.

KEY POINTS: • Diffusion and perfusion characteristics are assessable with only three b-values. • Association of b = 0, 50, 800 s/mm2is superior to b = 0, 250, 800 s/mm2. • A fourth acquired b-value has no benefit for differential diagnosis. • For liver lesion characterisation, simplified IVIM analysis is superior to ADC determination. • Simplified IVIM approach guarantees numerically stable, voxel-wise results and short acquisition times.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Mürtz P, Sprinkart AM, Reick M, et al. Accurate IVIM model-based liver lesion characterisation can be achieved with only three b-value DWI. Eur Radiol. 2018. PMID: 29671057. doi:10.1007/s00330-018-5401-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。