文献速递腹部技术与安全CT

两种计算机辅助检测(CAD)程序识别结直肠息肉的比较:性能与敏感度分析、当前局限及放射科医生实用建议

A comparison of computer-assisted detection (CAD) programs for the identification of colorectal polyps: performance and sensitivity analysis, current limitations and practical tips for radiologists.
PubMed 文献 · Clin Radiol · 2018-03-27

该回顾性单中心研究比较两种商用CAD程序在CT结肠成像(CTC)中检测结直肠息肉的敏感度、阳性预测值(PPV)和分析时间,以结肠镜为参考标准。CAD1敏感度89.8%、PPV 17.6%、平均分析时间125.8秒;CAD2敏感度75.5%、PPV 44.0%、平均分析时间84.6秒。作者结论认为现行商用CAD程序间性能差异大,敏感度与PPV之间存在权衡,相关信息应常规公开以供选择。

要点

  • CAD1敏感度89.8%、PPV 17.6%,CAD2敏感度75.5%、PPV 44.0%,两者敏感度与PPV呈权衡关系。
  • CAD1平均分析时间125.8秒,CAD2平均分析时间84.6秒,程序间分析速度差异明显。
  • 作者认为现行商用CAD程序性能仍有改进空间,相关信息应常规提供以辅助放射科医生决策。

核心结论

  • 现行商用CAD程序检测结直肠息肉的敏感度、PPV和分析时间差异较大,敏感度与PPV之间通常存在权衡,进一步开发应同时优化两者。

研究设计与样本

  • 回顾性单中心研究,纳入在CT结肠成像(CTC)上发现结直肠息肉并随后接受下消化道内镜检查的患者,使用两种商用CAD程序(CAD1和CAD2)分析,以结肠镜为参考标准计算敏感度和PPV并记录CAD分析时间。

诊断标准与关键数值

  • 以结肠镜为参考标准:CAD1检测结直肠息肉的敏感度89.8%、PPV 17.6%、平均分析时间125.8秒;CAD2敏感度75.5%、PPV 44.0%、平均分析时间84.6秒。

临床应用与阅片要点

  • 作者认为CAD程序的敏感度、PPV和分析时间信息应常规公开,以便对其使用做出知情选择,并可能影响放射科医生对CAD结果的使用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To directly compare the accuracy and speed of analysis of two commercially available computer-assisted detection (CAD) programs in detecting colorectal polyps.

MATERIALS AND METHOD: In this retrospective single-centre study, patients who had colorectal polyps identified on computed tomography colonography (CTC) and subsequent lower gastrointestinal endoscopy, were analysed using two commercially available CAD programs (CAD1 and CAD2). Results were compared against endoscopy to ascertain sensitivity and positive predictive value (PPV) for colorectal polyps. Time taken for CAD analysis was also calculated.

RESULTS: CAD1 demonstrated a sensitivity of 89.8%, PPV of 17.6% and mean analysis time of 125.8 seconds. CAD2 demonstrated a sensitivity of 75.5%, PPV of 44.0% and mean analysis time of 84.6 seconds.

CONCLUSION: The sensitivity and PPV for colorectal polyps and CAD analysis times can vary widely between current commercially available CAD programs. There is still room for improvement. Generally, there is a trade-off between sensitivity and PPV, and so further developments should aim to optimise both. Information on these factors should be made routinely available, so that an informed choice on their use can be made. This information could also potentially influence the radiologist's use of CAD results.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Bell LTO, Gandhi S. A comparison of computer-assisted detection (CAD) programs for the identification of colorectal polyps: performance and sensitivity analysis, current limitations and practical tips for radiologists. Clin Radiol. 2018. PMID: 29602538. doi:10.1016/j.crad.2018.02.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。