实时超声成像评估躯干稳定肌的可靠性:一项系统综述
该系统综述检索2007年6月至2017年8月多个数据库,纳入26项关于康复性超声评估深层腹部和腰椎躯干肌尺寸可靠性的原始研究,其中16项为高质量方法学。除2项外,所有高质量研究报告的组内相关系数(ICC)在评估者内可靠性为0.70或以上,评估者间可靠性ICC通常大于0.70;低质量研究的ICC范围分别为0.26-0.99和0.68-0.97,测量标准误和最小可检测变化一般在可接受范围。总体上,康复性超声成像具有较好的评估者内和评估者间可靠性。
要点
- 高质量研究显示康复性超声评估躯干稳定肌的评估者内可靠性ICC≥0.70(除2项研究外)。
- 高质量研究中评估者间可靠性ICC通常大于0.70。
- 低质量研究报告的ICC范围较宽:评估者内0.26-0.99,评估者间0.68-0.97。
核心结论
- 康复性超声成像对深层腹部和腰椎躯干肌尺寸的评估者内和评估者间可靠性总体良好。
研究设计与样本
- 系统综述,检索PubMed/MEDLINE、Scopus、Google Scholar、Science Direct、Embase、Physiotherapy Evidence、Ovid和CINAHL数据库,纳入2007年6月至2017年8月发表的26项原始研究,由2名独立评价者进行质量评价。
诊断标准与关键数值
- 高质量研究(16项)中,除2项外,评估者内可靠性ICC≥0.70;评估者间可靠性ICC通常大于0.70。低质量研究中,评估者内ICC为0.26-0.99,评估者间ICC为0.68-0.97。测量标准误和最小可检测变化一般在可接受范围。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Rehabilitative ultrasound (US) imaging is one of the popular methods for investigating muscle morphologic characteristics and dimensions in recent years. The reliability of this method has been investigated in different studies. As studies have been performed with different designs and quality, reported values of rehabilitative US have a wide range. The objective of this study was to systematically review the literature conducted on the reliability of rehabilitative US imaging for the assessment of deep abdominal and lumbar trunk muscle dimensions. The PubMed/MEDLINE, Scopus, Google Scholar, Science Direct, Embase, Physiotherapy Evidence, Ovid, and CINAHL databases were searched to identify original research articles conducted on the reliability of rehabilitative US imaging published from June 2007 to August 2017. The articles were qualitatively assessed; reliability data were extracted; and the methodological quality was evaluated by 2 independent reviewers. Of the 26 included studies, 16 were considered of high methodological quality. Except for 2 studies, all high-quality studies reported intraclass correlation coefficients (ICCs) for intra-rater reliability of 0.70 or greater. Also, ICCs reported for inter-rater reliability in high-quality studies were generally greater than 0.70. Among low-quality studies, reported ICCs ranged from 0.26 to 0.99 and 0.68 to 0.97 for intra- and inter-rater reliability, respectively. Also, the reported standard error of measurement and minimal detectable change for rehabilitative US were generally in an acceptable range. Generally, the results of the reviewed studies indicate that rehabilitative US imaging has good levels of both inter- and intra-rater reliability.
引用
- Taghipour M, Mohseni-Bandpei MA, Behtash H, et al. Reliability of Real-time Ultrasound Imaging for the Assessment of Trunk Stabilizer Muscles: A Systematic Review of the Literature. J Ultrasound Med. 2018. PMID: 29688574. doi:10.1002/jum.14661
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。