文献速递心血管MR

翻转角优化对对比增强bSSFP电影图像特征追踪应变评估精度与可重复性的影响

The effects of flip angle optimization on the precision and reproducibility of feature tracking derived strain assessment in contrast enhanced bSSFP cine images.
PubMed 文献 · Eur J Radiol · 2018-03-01

在1.5T下对20名受试者采集增强前后bSSFP中部短轴电影图像,对比增强后未调整翻转角(50°)的峰值收缩期周向应变显著低于未增强图像(-16.45±5.1% vs -20.57±6.2%,p<0.001),调整翻转角至100°后与未增强图像一致性变强,且观察者内和观察者间变异性略低。

要点

  • 对比增强后未调整翻转角(50°)的bSSFP图像所测应变较未增强图像低估约4%。
  • 将翻转角调整至100°后,增强与未增强图像所测应变一致性变强。
  • 调整翻转角后增强图像应变的观察者内和观察者间变异性略低于未增强图像。

核心结论

  • 若进行翻转角调整,基于特征追踪的应变分析可在对比增强bSSFP电影图像上进行而不损失精度和准确度。

研究设计与样本

  • 在1.5T下采集增强前(翻转角50°)和注射双倍剂量钆布醇后5分钟(翻转角50°、80°、90°、100°)的平衡SSFP中部短轴电影图像,共20名受试者,计算特征追踪收缩期周向应变并评估观察者内和观察者间变异性。

诊断标准与关键数值

  • 未调整翻转角(50°)的对比增强bSSFP图像所测中部峰值收缩期周向应变为-16.45±5.1%,低于未增强bSSFP图像的-20.57±6.2%(p<0.001)。
  • 未调整翻转角(50°)的增强与未增强图像应变平均差异为-4.13±2.4(95%CI:-5.3至-3),一致性低。
  • 调整翻转角至100°后,增强图像应变(-20.57±6%)与未增强图像应变的平均差异为0.01±0.9(CI:-0.43至0.41),一致性强。
  • 未增强图像应变的观察者内变异性为2.9%、观察者间为3.9%;调整翻转角(100°)的增强图像应变观察者内为2.5%、观察者间为2.3%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to investigate whether a flip angle adaptation, which is known to improve SNR and CNR in post contrast SSFP imaging, improves the precision and reproducibility of Feature Tracking (FT) derived strain assessments in post contrast bSSFP imaging.

METHODS AND RESULTS: At 1.5T balanced SSFP midventricular short axis cine images were acquired with various flip angles (FA) before (FA = 50°) and 5 min after (FAs = 50°, 80°, 90°, 100°) injection of double dose Gadobutrol. FT derived systolic circumferential strain was then calculated for all pre- and post-contrast images, the intra- and inter-observer variability of strain measurements was assessed. FT derived midventricular peak systolic circumferential strain (PSCS) derived from unadapted (FA: 50°) contrast enhanced bSSFP images was significantly lower than strain derived from unenhanced bSSFP images (-16.45 ± 5.1% vs -20.57 ± 6.2%; p < 0.001) and showed low agreement (mean difference of -4.13 ± 2.4, 95% CI:-5.3 to -3) in all 20 subjects. After adaption of the flip angle (FA: 100°), agreement between strain derived from unenhanced and adapted contrast enhanced bSSFP images (-20.57 ± 6%) was strong (0.01 ± 0.9, CI:-0.43 to 0.41). In comparison to intra- and interobserver variability of strain derived from unenhanced images (intra 2.9%; inter: 3.9%), strain measurements derived from adapted contrast enhanced images (FA: 100°) showed a slightly lower variability (intra: 2.5%; inter: 2.3%).

CONCLUSION: If flip angle adaptation is performed, FT based strain analysis may be performed on contrast enhanced bSSFP cine images without loss of precision and accuracy.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Kuetting DLR, Feisst A, Dabir D, et al. The effects of flip angle optimization on the precision and reproducibility of feature tracking derived strain assessment in contrast enhanced bSSFP cine images. Eur J Radiol. 2018. PMID: 29685551. doi:10.1016/j.ejrad.2018.02.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。