Tmax是腺苷负荷下静态PET成像所确定的敏感心肌缺血指标:一项猪模型研究
研究以8只左前降支狭窄50-90%的巴马小型猪为对象,行腺苷负荷心肌CT灌注与13NNH3 PET灌注成像,以PET为参考标准评估Tmax诊断心肌缺血的效能。结果显示缺血节段Tmax显著高于非缺血节段,Tmax的ROC曲线优于MBF或TTP,但与MBV无统计学差异,且Tmax优于MBF+MBV组合。
要点
- Tmax是动态负荷CTP中诊断心肌缺血的良好指标,敏感度和阴性预测值表现突出。
- 缺血节段的Tmax显著高于非缺血节段。
- Tmax诊断效能优于MBF或TTP,但与MBV无统计学差异。
核心结论
- 动态负荷CTP中的Tmax对检测心肌缺血具有良好的诊断准确度,尤其在敏感度和阴性预测值方面,与PET方法相比具有优势。
研究设计与样本
- 动物实验研究,8只巴马小型猪建立左前降支50-90%狭窄模型,行腺苷负荷心肌CT灌注成像和13NNH3 PET灌注成像,以PET结果作为缺血或非缺血的参考标准。
关键影像表现/征象
- 缺血节段的Tmax显著高于非缺血节段。
诊断标准与关键数值
- 以PET为参考标准计算Tmax等CTP参数的敏感度、特异度、阳性预测值、阴性预测值和准确度。
- ROC曲线多重比较显示Tmax优于MBF或TTP,但与MBV无统计学差异。
- Tmax优于MBF+MBV组合,但不优于MBF+TTP或MBV+TTP组合。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate Tmax, defined as the time of residual function R(t) reaching its maximum, as an indicator of myocardial ischaemia and compare its efficacy with other computed tomography perfusion (CTP) parameters.
MATERIALS AND METHODS: Eight Bama miniature pigs with 50-90% left anterior descending artery stenosis underwent adenosine stress myocardial CTP and 13NNH3 position-emission tomography (PET) perfusion imaging. Tmax, myocardial blood flow (MBF), myocardial blood volume (MBV), mean transit time (MTT), and time to peak (TTP) were calculated from CTP images. PET images were evaluated as ischaemia or non-ischaemia. Using PET as a reference standard, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated. Multiple comparisons of the receiver operating characteristic (ROC) curves between Tmax and other parameters were performed. The diagnostic performance of the combination of each two parameters was calculated and compared with Tmax. RESULTS: Tmax was significantly higher in ischaemic segments compared with non-ischaemic segments. Multiple comparisons of the ROCs indicated that Tmax was better than MBF or TTP but not statistically different from MBV. Tmax was superior to the combination of (MBF + MBV) but not to (MBF + TTP) or (MBV + TTP).
CONCLUSION: Tmax in dynamic stress CTP provides good diagnostic accuracy for detecting myocardial ischaemia, especially in sensitivity and NPV, compared with PET method. Tmax has better performance than MBF or TTP or combination of (MBF + MBV) in diagnosing myocardial ischaemia.
引用
- Sui S, Hou Y, Ma Y, et al. Tmax is a sensitive indicator of myocardial ischaemia under adenosine stress as determined by static PET imaging: a study in a porcine model. Clin Radiol. 2018. PMID: 29606367. doi:10.1016/j.crad.2018.02.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。