新型冠状动脉CT血管成像算法的诊断性能:用于诊断准确性的周期内CT运动校正算法的前瞻性多中心验证

Diagnostic Performance of a Novel Coronary CT Angiography Algorithm: Prospective Multicenter Validation of an Intracycle CT Motion Correction Algorithm for Diagnostic Accuracy.
PubMed 文献 · AJR Am J Roentgenol · 2018-04-18

这项前瞻性国际多中心研究纳入230例疑似冠心病患者,在未使用降心率药物的情况下行研究性CCTA,比较运动校正算法与标准重建对阻塞性CAD(≥50%狭窄)的诊断性能,以ICA为参考标准。运动校正算法减少了不可诊断扫描(20.4% vs 34.8%,p<0.001),按血管诊断准确率优于标准重建(77% vs 72%,p=0.02),按患者诊断准确率无显著差异(62% vs 59%,p=0.28)。

要点

  • 运动校正算法较标准重建减少不可诊断扫描:20.4% vs 34.8%(p<0.001)。
  • 按血管诊断准确率运动校正算法77% vs 标准重建72%(p=0.02)。
  • 按患者诊断准确率62% vs 59%(p=0.28),无显著差异。

核心结论

  • 运动校正算法减少伪影,在按血管分析和特定亚组(严重阻塞性≥70%狭窄、心率≥70次/分、房室沟血管)中提高对阻塞性CAD的诊断性能,按患者分析诊断准确率与标准重建无显著差异。

研究设计与样本

  • 前瞻性国际多中心研究,230例临床指征行ICA的疑似CAD患者,在未使用降心率药物前行研究性CCTA,比较运动校正算法与标准重建的盲法核心实验室判读,以ICA为参考标准。

诊断标准与关键数值

  • 阻塞性CAD定义为ICA示≥50%狭窄;因伪影无法评估的节段视为阻塞性。
  • 运动校正算法不可诊断扫描20.4% vs 标准重建34.8%(p<0.001)。
  • 按患者诊断准确率:运动校正算法62%(95%CI 56-68%)vs 标准重建59%(95%CI 53-66%),p=0.28。
  • 按血管诊断准确率:运动校正算法77%(95%CI 74-80%)vs 标准重建72%(95%CI 69-75%),p=0.02。

临床应用与阅片要点

  • 平均心率68.0±11.7次/分条件下,运动校正算法较标准重建减少不可诊断扫描。
  • 运动校正算法在严重阻塞性(≥70%)狭窄、心率≥70次/分及房室沟血管亚组中诊断性能更优。
  • 因伪影无法评估的节段按阻塞性处理,判读时需注意该定义对诊断准确率的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Motion artifact can reduce the diagnostic accuracy of coronary CT angiography (CCTA) for coronary artery disease (CAD). The purpose of this study was to compare the diagnostic performance of an algorithm dedicated to correcting coronary motion artifact with the performance of standard reconstruction methods in a prospective international multicenter study.

SUBJECTS AND METHODS: Patients referred for clinically indicated invasive coronary angiography (ICA) for suspected CAD prospectively underwent an investigational CCTA examination free from heart rate-lowering medications before they underwent ICA. Blinded core laboratory interpretations of motion-corrected and standard reconstructions for obstructive CAD (≥ 50% stenosis) were compared with ICA findings. Segments unevaluable owing to artifact were considered obstructive. The primary endpoint was per-subject diagnostic accuracy of the intracycle motion correction algorithm for obstructive CAD found at ICA.

RESULTS: Among 230 patients who underwent CCTA with the motion correction algorithm and standard reconstruction, 92 (40.0%) had obstructive CAD on the basis of ICA findings. At a mean heart rate of 68.0 ± 11.7 beats/min, the motion correction algorithm reduced the number of nondiagnostic scans compared with standard reconstruction (20.4% vs 34.8%; p < 0.001). Diagnostic accuracy for obstructive CAD with the motion correction algorithm (62%; 95% CI, 56-68%) was not significantly different from that of standard reconstruction on a per-subject basis (59%; 95% CI, 53-66%; p = 0.28) but was superior on a per-vessel basis: 77% (95% CI, 74-80%) versus 72% (95% CI, 69-75%) (p = 0.02). The motion correction algorithm was superior in subgroups of patients with severely obstructive (≥ 70%) stenosis, heart rate ≥ 70 beats/min, and vessels in the atrioventricular groove.

CONCLUSION: The motion correction algorithm studied reduces artifacts and improves diagnostic performance for obstructive CAD on a per-vessel basis and in selected subgroups on a per-subject basis.