肥厚型心肌病患者非对比剂T1加权MR图像的纹理分析与机器学习初步结果
该回顾性研究纳入32例已知肥厚型心肌病患者与30例心脏磁共振正常的对照者,在非对比剂T1加权短轴图像上提取左心室纹理特征,经降维和特征选择后比较组间差异并评估机器学习模型诊断效能。结果显示4个纹理特征在组间存在显著差异,单个参数GLevNonU区分肥厚型心肌病与对照的敏感度/特异度为91%/93%,以GLevNonU≥46为界值可达94%/90%,在无晚期钆增强的患者中该界值区分患者与健康对照的敏感度100%、特异度90%。
要点
- 非对比剂T1加权图像纹理分析可区分肥厚型心肌病与正常心肌,GLevNonU≥46时敏感度94%、特异度90%。
- 即使无晚期钆增强,GLevNonU界值仍以100%敏感度、90%特异度区分患者与健康对照。
- GLevNonU单参数模型区分肥厚型心肌病与对照的敏感度/特异度为91%/93%。
核心结论
- 非对比剂T1加权图像纹理分析能以很高准确度检出肥厚型心肌病的心肌组织改变,可能为无对比剂评估心肌纹理改变提供新参数。
研究设计与样本
- 回顾性、经机构审查委员会批准的研究,纳入32例已知肥厚型心肌病患者,30例心脏磁共振正常者作为对照,在短轴非对比剂T1加权图像上勾画包含左心室的感兴趣区进行纹理分析,采用逐步降维和纹理特征选择筛选特征。
关键影像表现/征象
- 肥厚型心肌病组与对照组比较,灰阶不均匀性(GLevNonU)为74±17 vs 38±9,p<.001。
- 低频子带小波系数能量(WavEnLL)为58±5 vs 48±10,p<.001。
- Fraction为0.70±0.07 vs 0.78±0.05,p<.001。
- Sum Average为16.6±0.4 vs 17.0±0.5,p=.007。
诊断标准与关键数值
- 含单个参数GLevNonU的模型区分肥厚型心肌病与对照的敏感度/特异度为91%/93%。
- GLevNonU≥46为界值区分肥厚型心肌病与对照的敏感度/特异度为94%/90%。
- 在无晚期钆增强的患者中,该界值区分患者与健康对照的敏感度100%、特异度90%。
临床应用与阅片要点
- 可在非对比剂T1加权短轴图像上勾画包含左心室的感兴趣区行纹理分析,关注GLevNonU等纹理参数。
- 原文结论认为纹理分析可能为无对比剂评估心肌纹理改变提供新参数。
局限性
- 原文标题标明为初步结果(Preliminary results)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To test in a first proof-of-concept study whether texture analysis (TA) allows for the detection of myocardial tissue alterations in hypertrophic cardiomyopathy (HCM) on non-contrast T1-weighted cardiac magnetic resonance (CMR) images using machine learning based approaches.
METHODS: This retrospective, IRB-approved study included 32 patients with known HCM. Thirty patients with normal CMR served as controls. Regions-of-interest for TA encompassing the left ventricle were drawn on short-axis non-contrast T1-weighted images using a freely available software package. Step-wise dimension reduction and texture feature selection was performed for selecting features enabling the detection of myocardial tissue alterations in HCM patients on non-contrast T1-weighted CMR images.
RESULTS: Comparing HCM patients and controls, four texture features were identified showing significant differences between groups (Grey-level Non-uniformity [GLevNonU]: 74 ± 17 vs. 38 ± 9, p < .001; Energy of wavelet coefficients in low-frequency sub-bands [WavEnLL]: 58 ± 5 vs. 48 ± 10, p < .001; Fraction: 0.70 ± 0.07 vs. 0.78 ± 0.05, p < .001; Sum Average: 16.6 ± 0.4 vs. 17.0 ± 0.5, p = .007). A model containing the single parameter GLevNonU proved to be the best for differentiating between HCM patients and controls with a sensitivity/specificity of 91%/93%. A cut-off of GLevNonU ≥46 allowed for distinguishing HCM patients from controls with a sensitivity/specificity of 94%/90%. Even in patients without late gadolinium enhancement (LGE), the defined cut-off led to a differentiation of LGE- patients from healthy controls with 100% sensitivity and 90% specificity.
CONCLUSIONS: TA on non-contrast T1-weighted images allows for the detection of myocardial tissue alterations in the setting of HCM with excellent accuracy, delivering potential novel parameters for a non-contrast assessment of myocardial texture alterations.
引用
- Baeßler B, Mannil M, Maintz D, et al. Texture analysis and machine learning of non-contrast T1-weighted MR images in patients with hypertrophic cardiomyopathy-Preliminary results. Eur J Radiol. 2018. PMID: 29685546. doi:10.1016/j.ejrad.2018.03.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。