文献速递心血管CT

减影CT血管造影改善严重钙化或支架患者显著冠状动脉疾病的评估——C-Sub 320多中心试验

Subtraction CT angiography improves evaluation of significant coronary artery disease in patients with severe calcifications or stents-the C-Sub 320 multicenter trial.
PubMed 文献 · Eur Radiol · 2018-04-25

这项前瞻性多中心研究纳入180例拟行有创冠状动脉造影的症状性患者,比较常规冠状动脉CT血管造影(CCTAconv)与减影冠状动脉CT血管造影(CCTAsub)对显著狭窄的评估。在无配准伪影的目标节段中,CCTAsub将假阳性率从72%降至33%,但以7%的假阴性率为代价;配准伪影在CCTAsub中常见。

要点

  • 在无配准伪影的钙化或支架节段,减影CT将假阳性率从72%降至33%。
  • 减影CT的代价是7%的假阴性率,且配准伪影频繁发生。
  • 严重钙化或支架患者中,减影CT可减少假阳性评估。

核心结论

  • 在严重钙化冠状动脉或支架中,减影CT在配准良好、常规CCTA怀疑显著狭窄的钙化或支架节段可降低假阳性率,但配准伪影在减影CT中常见。

研究设计与样本

  • 前瞻性多中心试验,2013-2016年在三家国际中心纳入180例拟行有创冠状动脉造影的症状性患者,最终104例(14%女性,平均年龄67岁,Agatston评分中位数852)纳入分析,比较常规与减影冠状动脉CT血管造影数据与有创冠状动脉造影。

诊断标准与关键数值

  • 目标节段定义为无运动伪影、因钙化或支架 blooming 可能致管腔狭窄>50%的冠状动脉节段;以有创冠状动脉造影为参考,无配准伪影目标节段中常规CCTA假阳性率72%(95%CI 63-80%),减影CCTA假阳性率33%(95%CI 25-42%),减影CCTA假阴性率7%(95%CI 3-14%)。

临床应用与阅片要点

  • 在严重钙化或支架患者中,减影CT在可评估时可能减少假阳性狭窄评估,从而可能减少不必要的下游检查;但需注意配准伪影频繁,出现配准伪影时评估被省略。

局限性

  • 排除76例患者后仅104例纳入分析。
  • 减影CT重建过程中配准伪影频繁,出现配准伪影时节段评估被省略。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Diagnostic accuracy of conventional coronary CT angiography (CCTAconv) may be compromised by blooming artifacts from calcifications or stents. Blooming artifacts may be reduced by subtraction coronary CT angiography (CCTAsub) in which non-contrast and contrast CT data sets are subtracted digitally. We tested whether CCTAsub in patients with severe coronary calcification or stents reduces the number of false-positive stenosis evaluations compared with CCTAconv.

METHODS: In this study, 180 symptomatic patients scheduled for invasive coronary angiography (ICA) were prospectively enrolled and CT scanned (2013-2016) at three international centers. CCTAconv, and CCTAsub data sets were reconstructed. Target segments were defined as motion-free coronary segments with a suspected stenosis (> 50% of lumen) potentially due to blooming of either calcium or stents. Target segments were evaluated with respect to misregistration artifacts from the CCTAsub reconstruction process, in which case evaluation was omitted. CCTAsub and CCTAconv were compared with ICA. Primary outcome measure was the frequency of false positives by CCTAconv versus CCTAsub to identify > 50% coronary stenosis by ICA on a per-segment level.

RESULTS: After exclusion of 76 patients, 104 (14% females) with mean age 67 years and median Agatston score 852 were included. There were 136 target segments with misregistration and 121 target segments without. Accuracy calculations in target segments without misregistration showed a reduction of the false positives from 72% [95% confidence interval (CI): 63-80%] in CCTAconv to 33% (CI:25-42%) in CCTAsub, at the expense of 7% (CI:3-14%) false negatives in CCTAsub.

CONCLUSIONS: In severely calcified coronary arteries or stents, CCTAsub reduces the false-positive rate in well-aligned, calcified or stent segments suspected of significant stenosis on CCTAconv. Nevertheless, misregistration artifacts are frequent in CCTAsub.

KEY POINTS: • A high calcium-score reduces the diagnostic accuracy in patients scanned with cardiac CT. • These patients would normally need an invasive angiogram for diagnosis. • In this prospective, multicenter study, subtraction CT, when evaluable, reduces false-positive stenosis evaluations. • Subtraction coronary CT angiography may, when evaluable, reduce excessive downstream testing.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Fuchs A, Kühl JT, Chen MY, et al. Subtraction CT angiography improves evaluation of significant coronary artery disease in patients with severe calcifications or stents-the C-Sub 320 multicenter trial. Eur Radiol. 2018. PMID: 29696430. doi:10.1007/s00330-018-5418-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。