文献速递心血管MRUS

心脏磁共振T1 mapping与超声心动图多维斑点追踪应变检测心脏移植受者急性细胞排斥反应

T1 Mapping by Cardiac Magnetic Resonance and Multidimensional Speckle-Tracking Strain by Echocardiography for the Detection of Acute Cellular Rejection in Cardiac Allograft Recipients.
PubMed 文献 · JACC Cardiovasc Imaging · 2018-04-18

本研究回顾性分析49例心脏移植受者的系列心内膜心肌活检、导管检查和超声心动图,评估超声应变成像与心脏磁共振T1 mapping对急性细胞排斥反应的检测价值。结果显示,T1时间≥1,090 ms、细胞外容积≥32%、整体纵向应变>-14%和整体环周应变≥-24%定义≥2级排斥反应均达100%敏感度和100%阴性预测值;整体纵向应变>-16%联合T1时间≥1,060 ms定义1级排斥反应达91%敏感度和92%阴性预测值。作者认为T1 mapping和超声整体纵向应变可指导选择性心内膜心肌活检。

要点

  • T1时间≥1,090 ms、细胞外容积≥32%、整体纵向应变>-14%、整体环周应变≥-24%定义≥2级排斥反应敏感度均为100%,阴性预测值均为100%。
  • 整体纵向应变>-16%联合T1时间≥1,060 ms定义1级排斥反应,敏感度91%、阴性预测值92%。
  • 成功治疗后T1时间显著下降,提示T1 mapping可用于监测治疗反应。

核心结论

  • T1 mapping和超声整体纵向应变可指导选择性心内膜心肌活检,用于检测心脏移植受者的急性细胞排斥反应。

研究设计与样本

  • 回顾性研究,共49例心脏移植受者,按机构方案系列行心内膜心肌活检、导管检查和超声心动图;第一部分用Velocity Vector Imaging测量16节段整体纵向应变和环周应变,第二部分加入心脏磁共振验证既往推导的应变截断值并评估T1测量准确性;所有检查在48小时内完成。

诊断标准与关键数值

  • T1时间≥1,090 ms定义≥2级排斥反应,敏感度100%、阴性预测值100%、阳性预测值70%。
  • 细胞外容积≥32%定义≥2级排斥反应,敏感度100%、阴性预测值100%、阳性预测值63%。
  • 整体纵向应变>-14%定义≥2级排斥反应,敏感度100%、阴性预测值100%、阳性预测值55%。
  • 整体环周应变≥-24%定义≥2级排斥反应,敏感度100%、阴性预测值100%、阳性预测值35%。
  • 整体纵向应变>-16%联合T1时间≥1,060 ms定义1级排斥反应,敏感度91%、阴性预测值92%。

临床应用与阅片要点

  • 整体纵向应变和整体环周应变在1级和≥2级排斥反应期间均显著恶化,且为任何排斥反应的独立预测因子。
  • 成功治疗后T1时间显著下降。
  • T1 mapping和超声整体纵向应变可指导选择性心内膜心肌活检。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to test the hypothesis that echocardiographic strain imaging, by tracking subtle alterations in myocardial function, and cardiac magnetic resonance T1 mapping, by quantifying tissue properties, are useful and complement each other to detect acute cellular rejection in heart transplant recipients.

BACKGROUND: Noninvasive alternatives to endomyocardial biopsy are highly desirable to monitor acute cellular rejection.

METHODS: Surveillance endomyocardial biopsies, catheterizations, and echocardiograms performed serially according to institutional protocol since transplantation were retrospectively reviewed. Sixteen-segment global longitudinal strain (GLS) and circumferential strain were measured before, during, and after the first rejection and at 2 time points for patients without rejection using Velocity Vector Imaging for the first part of the study. The second part, with cardiac magnetic resonance added to the protocol, served to validate previously derived strain cutoffs, examine the progression of strain over time, and to determine the accuracy of strain and T1 measurements to define acute cellular rejection. All tests were performed within 48 h.

RESULTS: Median time to first rejection (16 grade 1 rejection, 15 grade ≥2 rejection) was 3 months (interquartile range: 3 to 36 months) in 49 patients. GLS and global circumferential strain worsened significantly during grade 1 rejection and ≥2 rejection and were independent predictors of any rejection. In the second part of the study, T1 time ≥1,090 ms, extracellular volume ≥32%, GLS >-14%, and global circumferential strain ≥-24% had 100% sensitivity and 100% negative predictive value to define grade ≥2 rejection with 70%, 63%, 55%, and 35% positive predictive values, respectively. The combination of GLS >-16% and T1 time ≥1,060 ms defined grade 1 rejection with 91% sensitivity and 92% negative predictive value. After successful treatment, T1 times decreased significantly.

CONCLUSIONS: T1 mapping and echocardiographic GLS can serve to guide endomyocardial biopsy selectively.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Sade LE, Hazirolan T, Kozan H, et al. T1 Mapping by Cardiac Magnetic Resonance and Multidimensional Speckle-Tracking Strain by Echocardiography for the Detection of Acute Cellular Rejection in Cardiac Allograft Recipients. JACC Cardiovasc Imaging. 2018. PMID: 29680337. doi:10.1016/j.jcmg.2018.02.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。