用于特异性检测心脏装置相关细菌感染的新型PET与近红外成像探针
本研究在大鼠皮下植入不锈钢医疗器械模型,比较荧光标记麦芽六糖探针(MDP)与F-18氟代麦芽六糖在金黄色葡萄球菌感染、非感染性炎症及无菌对照中的成像表现。结果显示MDP在感染组1小时聚集强度显著高于对照和非感染炎症组,F-18氟代麦芽六糖在非感染炎症中无显著聚集而F-18氟代脱氧葡萄糖有聚集。作者认为基于麦芽六糖的成像探针可能有助于植入心脏装置相关感染的特异性灵敏诊断。
要点
- MDP在感染大鼠注射后1小时聚集强度显著高于无菌对照和非感染炎症组,并持续超过24小时。
- F-18氟代麦芽六糖在非感染性炎症中无显著聚集,而F-18氟代脱氧葡萄糖在炎症区有聚集。
- F-18氟代麦芽六糖与F-18氟代脱氧葡萄糖在感染区注射后30分钟均显著聚集。
核心结论
- 基于麦芽六糖的成像探针可能对植入心脏装置相关感染的特异性灵敏诊断有用。
研究设计与样本
- 动物实验:大鼠皮下植入不锈钢医疗器械模型,术后第4天分别注射金黄色葡萄球菌诱导轻度感染、松节油诱导非感染性炎症,无菌植入为对照;术后第6天静脉注射MDP或F-18氟代麦芽六糖后成像,另以F-18氟代脱氧葡萄糖行PET比较特异性,每组n=5至9。
关键影像表现/征象
- MDP在感染大鼠注射后1小时聚集强度为1.54±0.07,显著高于无菌对照组的1.26±0.04和非感染炎症组的1.20±0.05(p<0.05),并持续超过24小时。
- PET成像中,F-18氟代麦芽六糖与F-18氟代脱氧葡萄糖在注射后30分钟均于感染区显著聚集,最大标准摄取值比值分别为4.43±0.30和4.87±0.28。
- 无菌对照大鼠装置附近未见成像探针聚集。
- 非感染性炎症大鼠中F-18氟代麦芽六糖未见显著聚集,而F-18氟代脱氧葡萄糖在模型区聚集,最大标准摄取值分别为2.53±0.39和4.74±0.46(p<0.05)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to develop imaging agents to detect early stage infections in implantable cardiac devices.
BACKGROUND: Bacteria ingest maltodextrins through the specific maltodextrin transporter. We developed probes conjugated with either a fluorescent dye (maltohexaose fluorescent dye probe [MDP]) or a F-18 (F18 fluoromaltohexaose) and determined their usefulness in a model of infections associated with implanted cardiac devices.
METHODS: Stainless steel mock-ups of medical devices were implanted subcutaneously in rats. On post-operative day 4, animals were injected with either Staphylococcus aureus around the mock-ups to induce a relatively mild infection or oil of turpentine to induce noninfectious inflammation. Animals with a sterile implant were used as control subjects. On post-operative day 6, either the MDP or F18 fluoromaltohexaose was injected intravenously, and the animals were scanned with the appropriate imaging device. Additional positron emission tomography imaging studies were performed with F18-fluorodeoxyglucose as a comparison of the specificity of our probes (n = 5 to 9 per group).
RESULTS: The accumulation of the MDP in the infected rats was significantly increased at 1 h after injection when compared with the control and noninfectious inflammation groups (intensity ratio 1.54 ± 0.07 vs. 1.26 ± 0.04 and 1.20 ± 0.05, respectively; p < 0.05) and persisted for more than 24 h. In positron emission tomography imaging, both F18 fluoromaltohexaose and F18 fluorodeoxyglucose significantly accumulated in the infected area 30 min after the injection (maximum standard uptake value ratio 4.43 ± 0.30 and 4.87 ± 0.28, respectively). In control rats, there was no accumulation of imaging probes near the device. In the noninfectious inflammation rats, no significant accumulation was observed with F18 fluoromaltohexaose, but F18 fluorodeoxyglucose accumulated in the mock-up area (maximum standard uptake value 2.53 ± 0.39 vs. 4.74 ± 0.46, respectively; p < 0.05).
CONCLUSIONS: Our results indicate that maltohexaose-based imaging probes are potentially useful for the specific and sensitive diagnosis of infections associated with implantable cardiac devices.