文献速递妇产影像儿科影像心血管US

胎儿智能导航超声心动图(FINE)可检出98%的先天性心脏病

Fetal Intelligent Navigation Echocardiography (FINE) Detects 98% of Congenital Heart Disease.
PubMed 文献 · J Ultrasound Med · 2018-03-30

本病例对照研究纳入50例孕中晚期先天性心脏病胎儿与100例正常胎儿,利用四维超声时空图像相关(STIC)容积数据,由不同检查者采用胎儿智能导航超声心动图(FINE)分析。FINE产前检出先天性心脏病的敏感度为98%(49/50)、特异度为93%(93/100),阳性似然比14、阴性似然比0.02。

要点

  • FINE对先天性心脏病产前检出敏感度98%(49/50)、特异度93%(93/100)。
  • FINE诊断与最终确诊完全一致者占74%(37/50),次要差异12%(6/50),主要差异14%(7/50)。
  • FINE基于STIC容积数据自动生成并显示9个标准胎儿超声心动图切面。

核心结论

  • FINE在孕中晚期正常心脏与先天性心脏病胎儿中检出先天性心脏病的敏感度为98%(49/50)、特异度为93%(93/100)。
  • 作者认为由于FINE可识别广谱先天性心脏病且敏感度达98%,该方法可用于产前筛查和诊断先天性心脏病。

研究设计与样本

  • 病例对照研究,纳入50例广谱先天性心脏病胎儿(病例)与100例正常心脏胎儿(对照),孕中晚期。
  • 采用四维超声STIC技术采集容积数据,去除全部身份信息后随机分配给另一名研究者用FINE分析。
  • 以最终确诊的先天性心脏病为参考,计算FINE产前检出先天性心脏病的敏感度、特异度及阳性、阴性似然比。

关键影像表现/征象

  • FINE通过智能导航技术自动生成并显示9个标准胎儿超声心动图切面。

诊断标准与关键数值

  • FINE产前检出先天性心脏病:敏感度98%(49/50),特异度93%(93/100)。
  • 阳性似然比14,阴性似然比0.02。
  • 在确诊先天性心脏病病例中,FINE诊断与最终诊断完全一致74%(37/50),次要差异12%(6/50),主要差异14%(7/50)。

临床应用与阅片要点

  • FINE可基于STIC容积数据自动生成9个标准胎儿超声心动图切面用于产前筛查和诊断先天性心脏病。
  • 在确诊先天性心脏病病例中,FINE与最终诊断完全一致74%(37/50),次要差异12%(6/50),主要差异14%(7/50)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Fetal intelligent navigation echocardiography (FINE) is a novel method that automatically generates and displays 9 standard fetal echocardiographic views in normal hearts by applying intelligent navigation technology to spatiotemporal image correlation (STIC) volume data sets. The main objective was to determine the sensitivity and specificity of FINE in the prenatal detection of congenital heart disease (CHD).

METHODS: A case-control study was conducted in 50 fetuses with a broad spectrum of CHD (cases) and 100 fetuses with normal hearts (controls) in the second and third trimesters. Using 4-dimensional ultrasound with STIC technology, volume data sets were acquired. After all identifying information was removed, the data sets were randomly distributed to a different investigator for analysis using FINE. The sensitivity and specificity for the prenatal detection of CHD, as well as positive and negative likelihood ratios were determined.

RESULTS: The diagnostic performance of FINE for the prenatal detection of CHD was: sensitivity of 98% (49 of 50), specificity of 93% (93 of 100), positive likelihood ratio of 14, and negative likelihood ratio of 0.02. Among cases with confirmed CHD, the diagnosis with use of FINE completely matched the final diagnosis in 74% (37 of 50); minor discrepancies were seen in 12% (6 of 50), and major discrepancies were seen in 14% (7 of 50).

CONCLUSIONS: This is the first time the sensitivity and specificity of the FINE method in fetuses with normal hearts and CHD in the second and third trimesters has been reported. Because FINE identifies a broad spectrum of CHD with 98% sensitivity, this method could be used prenatally to screen for and diagnose CHD.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Yeo L, Luewan S, Romero R, et al. Fetal Intelligent Navigation Echocardiography (FINE) Detects 98% of Congenital Heart Disease. J Ultrasound Med. 2018. PMID: 29603310. doi:10.1002/jum.14616

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。