文献速递胸部CT

定量CT测量的重度肺气肿是否为放射性肺纤维化的负性危险因素

Is severe emphysema, as defined by quantitative CT measurement, a negative risk factor of radiation fibrosis?
PubMed 文献 · Br J Radiol · 2018-04-20

研究纳入68例接受75 Gy/30次放疗的I期非小细胞肺癌患者,用定量CT测量肺气肿严重程度。结果显示,发生放射性肺炎患者的LAA百分比(≤-860 HU和≤-950 HU)及平均HU均显著低于未发生者;全肺平均HU≤-850 HU时放疗后放射性肺炎发生率显著更低,提示定量CT平均HU可能预测放射性肺炎。

要点

  • 全肺平均HU≤-850 HU的患者放疗后放射性肺炎发生率显著更低(p=0.0003)。
  • 发生放射性肺炎者的LAA百分比(≤-860 HU、≤-950 HU)和平均HU均显著低于未发生者。
  • 平均HU的AUC显著高于LAA≤-860 HU和≤-950 HU的AUC(均p<0.0001)。

核心结论

  • 以全肺平均HU(≤-850 HU)评估的肺气肿患者在接受放疗后发生放射性肺炎的风险较低,定量CT平均HU可预测放疗后放射性肺炎。

研究设计与样本

  • 2011年3月至2015年6月连续纳入68例I期非小细胞肺癌患者,接受75 Gy/30次放疗,中位年龄79岁,男45例、女23例,T1 49例、T2 19例;用全肺LAA百分比(≤-860 HU或≤-950 HU)和平均HU评估肺气肿严重程度。

诊断标准与关键数值

  • 发生放射性肺炎患者的LAA≤-860 HU百分比均值差异显著低于未发生者(p=0.0004)。
  • 发生放射性肺炎患者的LAA≤-950 HU百分比均值差异显著低于未发生者(p=0.005)。
  • 发生放射性肺炎患者的平均HU均值差异显著低于未发生者(p=0.001)。
  • 平均HU的AUC显著高于LAA≤-860 HU的AUC(p<0.0001)和LAA≤-950 HU的AUC(p<0.0001)。
  • 全肺平均HU≤-850 HU时放疗后放射性肺炎发生率显著更低(p=0.0003)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate whether patients with emphysema, as evaluated by quantitative CT image measurement, are at risk of developing radiation pneumonitis (RP) after radiotherapy (RT) for non-small cell lung cancer (NSCLC).

METHODS: Between March 2011 and June 2015, 68 consecutive patients with Stage I NSCLC treated with a RT dose of 75 Gy given in 30 fractions were enrolled. The median age was 79 years and there were 45 males and 23 females. The number of patients with T1 and T2 were 49 and 19, respectively. The severity of emphysema was evaluated by the percentages of the low attenuation area (LAA) of ≤-860 or -950 Hounsfield unit (HU) and average HU in the whole lung.

RESULTS: The mean difference percentages of LAA of ≤-860 (p = 0.0004) or -950 HU (p = 0.005) and average HU (p = 0.001) in patients with RP were significantly lower than those in patients without RP. The area under curve (AUC) of average HU was significantly higher than AUC of LAA of ≤-860 (p < 0.0001) or -950 HU (p < 0.0001). The RP rate after RT was significantly lower when the average HU values were ≤-850 HU (p = 0.0003).

CONCLUSION: Patients with emphysema evaluated by average HU (≤-850 HU) in the whole lung were found to be at low risk of RP after RT. Advances in Knowledge: Quantitative measurement of average HU from CT images was predicted of RP after RT.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Saito T, Nakayama H, Yamada T, et al. Is severe emphysema, as defined by quantitative CT measurement, a negative risk factor of radiation fibrosis? Br J Radiol. 2018. PMID: 29651875. doi:10.1259/bjr.20170921

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。