使用ITK-SNAP对肺部肿瘤18F-FDG PET影像进行快速基于轮廓的分割:与专家分割的比较
该研究回顾性纳入76例胸部病灶的FDG PET图像,由4名评估者使用ITK-SNAP主动轮廓算法重复分割,并与6名评估者基于STAPLE算法生成的手工参考标准比较。ITK-SNAP的Dice系数为0.83、Hausdorff距离为12.6 mm,均优于基于阈值(41% VOI和50% VOI)的推荐PET肿瘤勾画方法。
要点
- ITK-SNAP主动轮廓分割肺部FDG PET肿瘤的Dice系数为0.83(95%CI 0.77–0.89),Hausdorff距离为12.6 mm(95%CI 9.82–15.32)。
- 基于阈值41% VOI的Dice系数为0.48(95%CI 0.44–0.51),基于阈值50% VOI的Dice系数为0.34(95%CI 0.30–0.38)。
- ITK-SNAP的评估者间ICC为0.94(95%CI 0.91–0.96),评估者内ICC均大于0.97。
核心结论
- ITK-SNAP对异质性胸部PET肿瘤的主动轮廓分割准确且可靠,其分割效果优于目前推荐的PET肿瘤勾画方法(与手工分割金标准相比)。
研究设计与样本
- 回顾性研究,纳入76例胸部病灶的FDG PET图像;由6名评估者手工分割并采用STAPLE算法生成优化参考标准,4名评估者使用ITK-SNAP主动轮廓算法对76例图像各分割两次;以Dice系数和Hausdorff距离评估准确性,以ICC评估信度。
诊断标准与关键数值
- ITK-SNAP主动轮廓分割的Dice系数为0.83(95%CI 0.77–0.89),Hausdorff距离为12.6 mm(95%CI 9.82–15.32)。
- 基于阈值41% VOI的Dice系数为0.48(95%CI 0.44–0.51),Hausdorff距离为25.6 mm(95%CI 21.7–31.4)。
- 基于阈值50% VOI的Dice系数为0.34(95%CI 0.30–0.38),Hausdorff距离为31.3 mm(95%CI 26.8–38.4)。
- ITK-SNAP的评估者间ICC为0.94(95%CI 0.91–0.96),评估者内ICC均大于0.97。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To assess the performance of the ITK-SNAP software for fluorodeoxyglucose (FDG) positron emission tomography (PET) segmentation of complex-shaped lung tumors compared with an optimized, expert-based manual reference standard. Materials and Methods Seventy-six FDG PET images of thoracic lesions were retrospectively segmented by using ITK-SNAP software. Each tumor was manually segmented by six raters to generate an optimized reference standard by using the simultaneous truth and performance level estimate algorithm. Four raters segmented 76 FDG PET images of lung tumors twice by using ITK-SNAP active contour algorithm. Accuracy of ITK-SNAP procedure was assessed by using Dice coefficient and Hausdorff metric. Interrater and intrarater reliability were estimated by using intraclass correlation coefficients of output volumes. Finally, the ITK-SNAP procedure was compared with currently recommended PET tumor delineation methods on the basis of thresholding at 41% volume of interest (VOI; VOI41) and 50% VOI (VOI50) of the tumor's maximal metabolism intensity. Results Accuracy estimates for the ITK-SNAP procedure indicated a Dice coefficient of 0.83 (95% confidence interval: 0.77, 0.89) and a Hausdorff distance of 12.6 mm (95% confidence interval: 9.82, 15.32). Interrater reliability was an intraclass correlation coefficient of 0.94 (95% confidence interval: 0.91, 0.96). The intrarater reliabilities were intraclass correlation coefficients above 0.97. Finally, VOI41 and VOI50 accuracy metrics were as follows: Dice coefficient, 0.48 (95% confidence interval: 0.44, 0.51) and 0.34 (95% confidence interval: 0.30, 0.38), respectively, and Hausdorff distance, 25.6 mm (95% confidence interval: 21.7, 31.4) and 31.3 mm (95% confidence interval: 26.8, 38.4), respectively. Conclusion ITK-SNAP is accurate and reliable for active-contour-based segmentation of heterogeneous thoracic PET tumors. ITK-SNAP surpassed the recommended PET methods compared with ground truth manual segmentation.
引用
- Besson FL, Henry T, Meyer C, et al. Rapid Contour-based Segmentation for 18F-FDG PET Imaging of Lung Tumors by Using ITK-SNAP: Comparison to Expert-based Segmentation. Radiology. 2018. PMID: 29613842. doi:10.1148/radiol.2018171756
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。