Tc-99m-MAA肝映射中的肝肺分流:与动态横断面影像的相关性及不同分流模式的描述
本回顾性研究纳入453例患者共523次Tc-99m-MAA肝动脉分支注射扫描,分析其与3个月内动态CT或MRI所示目标分流模式的相关性。342次横断面影像中,63次存在目标分流、271次无目标分流、8次不确定;存在目标分流时平均肺分流分数为12.9%±10.36%(95%CI 10.29-15.15%),无目标分流时为4.3%±3.17%(95%CI 3.93-4.68%),差异有统计学意义(P<0.001)。目标分流分为直接型(动脉-肝静脉分流)和间接型(动脉-门静脉分流合并门体分流)。
要点
- 动态CT或MRI上显示特定类型血管分流时,对应MAA扫描的肺分流分数较高。
- 目标分流包括直接型动脉-肝静脉分流和间接型动脉-门静脉分流合并门体分流。
- 存在目标分流者平均肺分流分数12.9%,无目标分流者4.3%,差异有统计学意义(P<0.001)。
核心结论
- 动态CT或MRI上显示特定模式的血管分流与较高的肺分流分数相关。
研究设计与样本
- 回顾性研究,经机构审查委员会批准并豁免知情同意;2007年7月至2015年6月共453例患者(301男、152女)的523次MAA扫描,选取MAA检查前3个月内的动态CT或MRI进行相关性分析;参考标准为动态CT或MRI上可能将肝动脉流入分流至体静脉回流的目标分流模式。
关键影像表现/征象
- 目标分流在动态CT或MRI上表现为直接型动脉-肝静脉分流或间接型动脉-门静脉分流合并门体分流。
- 342次动态CT或MRI中,目标分流存在63次、不存在271次、不确定8次。
诊断标准与关键数值
- 存在目标分流时,对应MAA扫描的平均肺分流分数为12.9%±10.36%(95%CI 10.29-15.15%)。
- 无目标分流时,平均肺分流分数为4.3%±3.17%(95%CI 3.93-4.68%)。
- 两组差异有统计学意义(P<0.001)。
临床应用与阅片要点
- 动态CT或MRI上识别直接型动脉-肝静脉分流或间接型动脉-门静脉分流合并门体分流,可能提示肺分流分数升高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The purpose of the study was to correlate lung shunt fraction (LSF) calculated by intra-arterial injection of Technetium-99m (Tc-99m)-labeled macroaggregated albumin (MAA) in a hepatic artery branch with the presence of certain patterns of vascular shunts on dynamic CT or MRI of the liver.
METHODS: This retrospective study was approved by the institutional review board and informed consent was waived. We reviewed 523 MAA scans in 453 patients (301 men, 152 women) performed from July 2007 to June 2015 and their correlative cross-sectional imaging. Patterns of vascular shunts on dynamic CT or MRI performed within 3 months of the MAA study and that potentially divert hepatic arterial inflow to the systemic venous return were defined as "target shunts." Dynamic CT or MRI was classified into three groups with target shunt present, absent, or indeterminate. The mean LSF was compared across the first and second groups using paired t test.
RESULTS: 342 CT and MRI studies met inclusion criteria: target shunts were present in 63 studies, absent in 271 studies, and 8 studies were indeterminate. When target shunts were visualized, the mean LSF on corresponding MAA scans was 12.9 ± 10.36% (95% CI 10.29-15.15%) compared to 4.3 ± 3.17% (95% CI 3.93-4.68%) when no target shunt was visualized. The difference was statistically significant (p value < 0.001). Identified target shunts were either direct (arteriohepatic venous shunt) or indirect (arterioportal shunt combined with a portosystemic shunt).
CONCLUSIONS: Visualizing certain patterns of vascular shunting on a dynamic CT or MRI scan is associated with high LSF.
引用
- Bermo M, Matesan MC, Itani M, et al. Hepatopulmonary shunting on Tc99m-MAA liver mapping: correlation with dynamic cross-sectional imaging and description of different shunting patterns. Abdom Radiol (NY). 2018. PMID: 29632990. doi:10.1007/s00261-018-1602-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。