数字胸部体层摄影检测与表征实性肺结节:瑞典心肺生物影像研究试点队列数据
基于1111名随机选取的50-64岁人群,其中125名CT发现≥5mm偶发结节者加做数字体层摄影(DTS),由4名胸部放射科医生盲法评估。DTS对CT证实≥5mm和≥6mm结节的检出率分别为49%-58%和48%-62%,JAFROC FOM分别为0.47和0.51,推荐随访的ROC AUC分别为0.62和0.65。结论认为常规使用DTS会导致检出率降低及推荐随访的小结节数量减少。
要点
- DTS对CT证实≥5mm结节的检出率为49%-58%,对≥6mm结节为48%-62%
- DTS推荐随访的ROC AUC对≥5mm和≥6mm结节分别为0.62和0.65
- 常规使用DTS会降低检出率并减少推荐随访的小结节数量
核心结论
- 常规使用DTS会导致检出率降低及推荐随访的小结节数量减少。
研究设计与样本
- 前瞻性研究,基于人群研究随机选取1111名50-64岁参与者,均接受包括胸部CT的医学评估。
- 其中125名CT发现≥5mm偶发结节者纳入本研究,在随访CT时加做DTS,检查于2012年3月至2014年10月进行。
- DTS图像由4名胸部放射科医生在不知真实结节数量的情况下分两次独立评估,分别按5mm(125名参与者)和6mm(55名参与者)的偶发结节随访阈值进行。
诊断标准与关键数值
- DTS对CT证实≥5mm结节的总体检出率范围为49%-58%。
- DTS对CT证实≥6mm结节的总体检出率范围为48%-62%。
- DTS检测CT证实≥5mm结节的JAFROC FOM为0.47。
- DTS检测CT证实≥6mm结节的JAFROC FOM为0.51。
- DTS推荐随访的ROC AUC对≥5mm结节为0.62。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To investigate the performance of digital tomosynthesis (DTS) for detection and characterization of incidental solid lung nodules. Materials and Methods This prospective study was based on a population study with 1111 randomly selected participants (age range, 50-64 years) who underwent a medical evaluation that included chest computed tomography (CT). Among these, 125 participants with incidental nodules 5 mm or larger were included in this study, which added DTS in conjunction with the follow-up CT and was performed between March 2012 and October 2014. DTS images were assessed by four thoracic radiologists blinded to the true number of nodules in two separate sessions according to the 5-mm (125 participants) and 6-mm (55 participants) cut-off for follow-up of incidental nodules. Pulmonary nodules were directly marked on the images by the readers and graded regarding confidence of presence and recommendation for follow-up. Statistical analyses included jackknife free-response receiver operating characteristic, receiver operating characteristic, and Cohen κ coefficient. Results Overall detection rate ranges of CT-proven nodules 5 mm or larger and 6 mm or larger were, respectively, 49%-58% and 48%-62%. Jackknife free-response receiver operating characteristics figure of merit for detection of CT-proven nodules 5 mm or larger and 6 mm or larger was 0.47 and 0.51, respectively, and area under the receiver operating characteristic curve regarding recommendation for follow-up was 0.62 and 0.65, respectively. Conclusion Routine use of DTS would result in lower detection rates and reduced number of small nodules recommended for follow-up. © RSNA, 2018.
引用
- Meltzer C, Vikgren J, Bergman B, et al. Detection and Characterization of Solid Pulmonary Nodules at Digital Chest Tomosynthesis: Data from a Cohort of the Pilot Swedish Cardiopulmonary Bioimage Study. Radiology. 2018. PMID: 29613826. doi:10.1148/radiol.2018171481
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。