文献速递胸部介入CT

术前使用医用胶黏剂对肺部磨玻璃结节进行定位以指导胸腔镜切除术

Preoperative localisation of pulmonary ground-glass opacity using medical adhesive before thoracoscopic resection.
PubMed 文献 · Eur Radiol · 2018-04-17

对188例孤立性磨玻璃结节(纯磨玻璃结节90例,混合性磨玻璃结节98例)患者,在胸腔镜手术前采用CT引导下医用胶黏剂α-氰基丙烯酸酯进行术前定位,评估其安全性和效率。结果显示定位成功率100%,所有磨玻璃结节均经胸腔镜成功切除,无症状性气胸发生率8.5%(16/188),轻度肺出血发生率7.9%(15/188),均无需进一步治疗。作者认为该定位方法安全、操作时间短、成功率高。

要点

  • CT引导下α-氰基丙烯酸酯医用胶定位磨玻璃结节,定位成功率100%。
  • 定位后无症状性气胸发生率8.5%(16/188),轻度肺出血7.9%(15/188),均无需进一步治疗。
  • 所有磨玻璃结节均经胸腔镜成功切除(100%)。

核心结论

  • CT引导下医用胶黏剂α-氰基丙烯酸酯术前定位安全、操作时间短,对胸腔镜切除磨玻璃结节具有高准确性和成功率。

研究设计与样本

  • 对188例连续孤立性磨玻璃结节患者(纯磨玻璃结节90例,混合性磨玻璃结节98例)在胸腔镜手术前实施CT引导下医用胶黏剂α-氰基丙烯酸酯定位,分析并发症和有效性,并对切除的磨玻璃结节进行病理分析。

诊断标准与关键数值

  • 定位操作平均时间16.3±5.2分钟。
  • 术前定位成功率100%。
  • 所有磨玻璃结节均经胸腔镜成功切除(100%)。
  • 无症状性气胸发生率8.5%(16/188)。
  • 轻度肺出血发生率7.9%(15/188)。

临床应用与阅片要点

  • 术前采用CT引导下α-氰基丙烯酸酯医用胶定位有助于胸腔镜成功切除磨玻璃结节。
  • 定位后无症状性气胸和轻度肺出血常见,但均无需进一步治疗。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the safety and efficiency of computed tomography (CT)-guided medical adhesive, α-cyanoacrylate, for preoperative localisation of pulmonary ground-glass opacity (GGO) used for guiding the video-assisted thoracoscopic surgical (VATS) excision METHODS: The procedure was performed on 188 consecutive patients with solitary GGO (pure GGO = 90 cases; mixed GGO = 98 cases) prior to the thoracoscopic procedure. The complications and efficacy of this method were analysed. The resected GGO was analysed pathologically.

RESULTS: The mean duration of the procedure was 16.3 ± 5.2 min. The preoperative localisation was 100% successful. All GGOs were successfully resected by VATS. Asymptomatic pneumothorax was developed in 16/188 patients (8.5%) and mild pulmonary haemorrhage occurred in 15 cases (7.9%) post-localisation. None of the patients required any further treatment for the complications.

CONCLUSION: Preoperative localisation using CT-guided medical adhesive, α-cyanoacrylate, is a safe and short-duration procedure, with high accuracy and success rates with respect to VATS resection of GGO.

KEY POINTS: • Preoperative localisation is crucial for successful resection of GGO by VATS. • Preoperative adhesive localisation provides an up to 100% successful localisation rate with few complications. • Preoperative adhesive localisation enabled VATS resection in 100% of the GGO. • Preoperative adhesive localisation is safe and effective for VATS resection of GGO.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Cen RL, Cui F, Wan Q, et al. Preoperative localisation of pulmonary ground-glass opacity using medical adhesive before thoracoscopic resection. Eur Radiol. 2018. PMID: 29666992. doi:10.1007/s00330-018-5394-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。