鼻咽癌锥形束CT引导放疗中5毫米边界可覆盖哪些局部摆位误差的分析
研究对24例鼻咽癌患者的323次锥形束CT扫描进行11个感兴趣区配准,分析锥形束CT引导放疗中5毫米边界能覆盖哪些局部摆位误差。结果显示仅C1ROI-C4ROI、下颌骨和蝶窦的上方局部摆位误差可被5毫米边界覆盖,且这些感兴趣区作为整体参考优于单独骨性标志。
要点
- 仅C1ROI-C4ROI、下颌骨和蝶窦的上方局部摆位误差可被5毫米边界覆盖。
- C1ROI-C4ROI、下颌骨和蝶窦在左右、上下、前后方向与PTVROI显著相关且一致。
- 上述感兴趣区在前后方向ROC分析结果显著,整体参考优于单独骨性标志。
核心结论
- 对于大感兴趣区的锥形束CT引导鼻咽癌放疗,仅C1ROI-C4ROI、下颌骨和蝶窦的上方局部摆位误差可被5毫米边界覆盖,将这些感兴趣区作为整体参考优于单独骨性标志。
研究设计与样本
- 对24例鼻咽癌患者共323次锥形束CT扫描进行11个感兴趣区配准,采用CTV-PTV/OAR-PRV边界分析、Pearson相关分析、Bland-Altman图和ROC分析。
诊断标准与关键数值
- C1ROI-C4ROI、下颌骨和蝶窦相对PTVROI的临床靶区-计划靶区/危及器官-计划危及器官边界均小于5毫米。
临床应用与阅片要点
- 作者认为本报告有助于临床实践中鼻咽癌放疗的锥形束CT配准,使用这些感兴趣区作为整体参考感兴趣区优于单独骨性标志。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To analyse which local set-up errors can be covered by a 5-mm margin for cone beam computed tomography (CBCT)-guided radiotherapy in nasopharyngeal carcinoma (NPC).
METHODS: 11 regions of interest (ROIs) were registered for 24 NPC patients, with a total of 323 CBCT scans. According to the registration results, clinical target volume-planning target volume (CTV-PTV)/organs at risk-planning risk volume (OAR-PRV) margin analysis; Pearson correlation analysis; Bland-Altman plots; and a receiver operating characteristic (ROC) analysis were used to investigate which local set-up errors of substructure can be represented by the PTVROI.
RESULTS: The clinical target volume-PTV/OAR-planning risk volume margins were less than 5 mm for C1ROI-C4ROI, mandible (MROI), and sphenoid sinus (SROI) with respect to PTVROI. C1ROI-C4ROI, MROI, and SROI exhibited significant correlations and consistencies in the mediolateral, superior-inferior, and anteroposterior (AP) directions and significant receiver operating characteristic analysis results in the anteroposterior direction.
CONCLUSION: Only the upper local set-up error of C1ROI-C4ROI, MROI, and SROI can be covered by a 5-mm margin for CBCT-guided NPC radiotherapy with a large ROI. Using these ROIs as an integral reference ROI is better than individual bony landmark. Advances in knowledge: This report is helpful to CBCT registration for NPC radiotherapy in clinical practice.
引用
- Zhong R, Song Y, Yan Y, et al. Analysis of which local set-up errors can be covered by a 5-mm margin for cone beam CT-guided radiotherapy for nasopharyngeal carcinoma. Br J Radiol. 2018. PMID: 29688742. doi:10.1259/bjr.20160849
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。