CT血管造影鉴别急性缺血性卒中颅外颈内动脉假性闭塞与真性闭塞或重度狭窄的准确性:MR CLEAN回顾性子研究
该回顾性研究纳入MR CLEAN试验中CTA显示颅外颈内动脉明显闭塞且有DSA的46例患者,比较CTA与DSA对动脉粥样硬化性闭塞/重度狭窄、夹层及假性闭塞的鉴别准确性;CTA检出假性闭塞的敏感度为82%(95% CI 57-96),观察者间κ值为.77,T型闭塞在假性闭塞中更常见(82% vs 21%,P < .001)。
要点
- CTA上颅外颈内动脉无对比剂充盈时,需鉴别动脉粥样硬化性闭塞/重度狭窄、夹层与假性闭塞。
- 假性闭塞的CTA征象为对比剂在颈动脉球上方逐渐变淡,尤其伴颅内颈内动脉分叉部闭塞(T型闭塞)时。
- CTA鉴别假性闭塞的敏感度为82%,特异度为76%和86%,观察者间一致性κ=.77。
核心结论
- CTA可鉴别颅外颈内动脉假性闭塞与真性颈动脉闭塞。
研究设计与样本
- 回顾性研究,为MR CLEAN多中心随机临床试验的子研究;476例中108例(23%)CTA显示明显的颅外颈动脉闭塞,其中46例有DSA图像;两名独立观察者将CTA分类为动脉粥样硬化性原因(闭塞/重度狭窄)、夹层或疑似假性闭塞,以DSA分类为参考标准。
关键影像表现/征象
- CTA上假性闭塞表现为对比剂在颈动脉球水平以上逐渐变淡。
- 疑似假性闭塞尤其见于颅内颈内动脉分叉部闭塞(T型闭塞)存在时。
- DSA显示动脉粥样硬化性原因13例(28%)、夹层16例(35%)、假性闭塞17例(37%)。
- T型闭塞在假性闭塞中比真性闭塞更常见(82% vs 21%,P < .001)。
诊断标准与关键数值
- CTA检出假性闭塞的敏感度为82%(95% CI,57-96),两名观察者相同。
- CTA检出假性闭塞的特异度观察者1为76%(95% CI,56-90),观察者2为86%(95% CI,68-96)。
- 观察者间一致性κ值为.77,提示高度一致。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: The absence of opacification on CTA in the extracranial ICA in acute ischemic stroke may be caused by atherosclerotic occlusion, dissection, or pseudo-occlusion. The latter is explained by sluggish or stagnant flow in a patent artery caused by a distal intracranial occlusion. This study aimed to explore the accuracy of CTA for differentiating pseudo-occlusion from true occlusion of the extracranial ICA.
MATERIALS AND METHODS: All patients from the Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands (MR CLEAN) with an apparent ICA occlusion on CTA and available DSA images were included. Two independent observers classified CTA images as atherosclerotic cause (occlusion/high-grade stenosis), dissection, or suspected pseudo-occlusion. Pseudo-occlusion was suspected if CTA showed a gradual contrast decline located above the level of the carotid bulb, especially in the presence of an occluded intracranial ICA bifurcation (T-occlusion). DSA images, classified into the same 3 categories, were used as the criterion standard.
RESULTS: In 108 of 476 patients (23%), CTA showed an apparent extracranial carotid occlusion. DSA was available in 46 of these, showing an atherosclerotic cause in 13 (28%), dissection in 16 (35%), and pseudo-occlusion in 17 (37%). The sensitivity for detecting pseudo-occlusion on CTA was 82% (95% CI, 57-96) for both observers; specificity was 76% (95% CI, 56-90) and 86% (95% CI, 68-96) for observers 1 and 2, respectively. The κ value for interobserver agreement was .77, indicating substantial agreement. T-occlusions were more frequent in pseudo- than true occlusions (82% versus 21%, P < .001).
CONCLUSIONS: On CTA, extracranial ICA pseudo-occlusions can be differentiated from true carotid occlusions.
引用
- Kappelhof M, Marquering HA, Berkhemer OA, et al. Accuracy of CT Angiography for Differentiating Pseudo-Occlusion from True Occlusion or High-Grade Stenosis of the Extracranial ICA in Acute Ischemic Stroke: A Retrospective MR CLEAN Substudy. AJNR Am J Neuroradiol. 2018. PMID: 29622556. doi:10.3174/ajnr.A5601
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。