脑磁共振弥散张量成像畸变校正方法中信号强度差异的最小化

Minimisation of Signal Intensity Differences in Distortion Correction Approaches of Brain Magnetic Resonance Diffusion Tensor Imaging.
PubMed 文献 · Eur Radiol · 2018-04-12

本研究评估b0图像与弥散张量成像(DTI)数据之间信号强度差异在图像配准过程中的影响,采用简单图像强度补偿(SIMIC)方法在配准前校正该差异,结果显示SIMIC结合两种代价函数获得最高DSC值(0.802 ± 0.007),仅使用归一化互相关(NCC)时部分脑区弥散标量值和纤维数目及长度呈现偏低趋势。

要点

  • SIMIC方法通过从DTI数据重新计算b0图像,可在配准前最小化信号强度差异。
  • SIMIC结合两种代价函数获得最高DSC值(0.802 ± 0.007)。
  • 仅使用NCC时,胼胝体、上纵束和皮质脊髓束的弥散标量值及纤维数目和长度呈现偏低趋势。

核心结论

  • 基于图像的畸变校正结合SIMIC可考虑作为DTI分析的一种额外选项,有助于将信号强度差异纳入图像分析。

研究设计与样本

  • 方法学研究,评估b0图像与DTI数据间信号强度差异在图像配准中的影响;采用SIMIC方法从DTI数据重新计算b0图像(b0ext),以两种代价函数将b0ext配准至MR扫描采集的b0图像(b0nd)并获得变换矩阵,再用于配准DTI数据;计算DSC值、弥散标量矩阵以及量化的纤维数目和长度。

关键影像表现/征象

  • SIMIC结合两种代价函数获得最高DSC值(0.802 ± 0.007)。
  • 仅使用归一化互相关(NCC)时,胼胝体、上纵束和皮质脊髓束的弥散标量值及纤维数目和长度呈现偏低趋势。

临床应用与阅片要点

  • 作者认为,基于图像的畸变校正结合SIMIC可考虑作为DTI分析的一种额外选项,有助于将信号强度差异纳入图像分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the effects of signal intensity differences between the b0 image and diffusion tensor imaging (DTI) in the image registration process.

METHODS: To correct signal intensity differences between the b0 image and DTI data, a simple image intensity compensation (SIMIC) method, which is a b0 image re-calculation process from DTI data, was applied before the image registration. The re-calculated b0 image (b0ext) from each diffusion direction was registered to the b0 image acquired through the MR scanning (b0nd) with two types of cost functions and their transformation matrices were acquired. These transformation matrices were then used to register the DTI data. For quantifications, the dice similarity coefficient (DSC) values, diffusion scalar matrix, and quantified fibre numbers and lengths were calculated.

RESULTS: The combined SIMIC method with two cost functions showed the highest DSC value (0.802 ± 0.007). Regarding diffusion scalar values and numbers and lengths of fibres from the corpus callosum, superior longitudinal fasciculus, and cortico-spinal tract, only using normalised cross correlation (NCC) showed a specific tendency toward lower values in the brain regions.

CONCLUSION: Image-based distortion correction with SIMIC for DTI data would help in image analysis by accounting for signal intensity differences as one additional option for DTI analysis.

KEY POINTS: • We evaluated the effects of signal intensity differences at DTI registration. • The non-diffusion-weighted image re-calculation process from DTI data was applied. • SIMIC can minimise the signal intensity differences at DTI registration.