文献速递神经MR

3DFLAIR在临床实践中对照双回波T2序列检测多发性硬化幕下病灶的诊断价值

Diagnostic value of 3DFLAIR in clinical practice for the detection of infratentorial lesions in multiple sclerosis in regard to dual echo T2 sequences.
PubMed 文献 · Eur J Radiol · 2018-03-15

该前瞻性研究基于OFSEP数据库回顾性分析164例多发性硬化患者,在四家中心的1.5T或3T设备上比较3DFLAIR与2DT2/PD对幕下病灶的检出。三名不同经验水平的阅片者独立计数,3DFLAIR检出的幕下病灶数显著高于2DT2/PD,ROC分析显示3DFLAIR更特异、更敏感,阅片者经验越丰富检出病灶越多。

要点

  • 3DFLAIR检出的幕下病灶数显著多于2DT2/PD(Rater-1:303 vs 528;Rater-2:370 vs 798)。
  • 3DFLAIR对三叉神经病灶的检出率也显著高于2DT2/PD。
  • ROC分析显示3DFLAIR较2DT2/PD更特异、更敏感。

核心结论

  • 在结合放射科医生经验水平的前提下,OFSEP优化的3DFLAIR较2DT2/PD可显著改善多发性硬化幕下病灶的检出。
  • 这对多发性硬化随访中依据新发病灶数量调整患者治疗具有重要意义。

研究设计与样本

  • 前瞻性研究,但基于OFSEP数据库对164例多发性硬化患者进行回顾性分析。
  • MR检查在四家中心的1.5T或3T系统上完成。
  • 由三名阅片者(初级住院医师、具有神经放射学专长的住院医师和资深神经放射科医师)独立在3DFLAIR和2DT2/PD上计数幕下病灶并分配至后颅窝不同区域。
  • 两种序列空间分辨率不同,但反映多数共识推荐及临床实践中的做法。

关键影像表现/征象

  • 幕下病灶总数:Rater-1为528个,Rater-2为798个。
  • 3DFLAIR检出病灶数:Rater-1为303个,Rater-2为370个,显著高于2DT2/PD。
  • 3DFLAIR检出的三叉神经病灶患病率显著高于2DT2/PD。
  • 三名阅片者之间观察到总体差异,阅片者经验越丰富检出病灶越多。

诊断标准与关键数值

  • ROC分析显示3DFLAIR较2DT2/PD更特异、更敏感(原文未报告具体敏感度、特异度或AUC数值)。

临床应用与阅片要点

  • 原文结论指出,结合放射科医生经验水平,OFSEP优化的3DFLAIR可显著改善多发性硬化幕下病灶检出。
  • 原文指出该结果对多发性硬化随访中依据新发病灶数量调整治疗具有重要意义。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The aim of this prospective study is to investigate and evaluate in clinical practice the diagnostic impact of 3DFLAIR in regards to 2DT2/PD in terms of infratentorial lesions detection in multiple sclerosis (MS).

MATERIAL AND METHODS: 164 MS patients from the OFSEP database were reviewed retrospectively. MR examinations were performed on 1.5T or 3T systems from four different centers. Infratentorial lesions were counted and allocated to different regions of the posterior fossa by three raters independently (junior resident, resident with an expertise in neuroradiology, and senior neuro-radiologist) on the 3DFLAIR and 2DT2/PD. Both sequences do not have the same spatial resolution but reflect what is recommended by most of the consensus and done in clinical practice.

RESULTS: With an overall number of 528 for Rater-1 and 798 for Rater-2 infratentorial lesions, 3DFLAIR had a significantly higher number of lesions detected than 2DT2/PD (303 for Rater-1 and 370 for Rater-2). The prevalence of trigeminal lesions detected by using 3DFLAIR was also significantly higher than 2DT2/PD. ROC analysis showed 3DFLAIR to be more specific and sensitive than 2DT2/PD. An overall difference between all three Raters has been observed. The more the Rater is experienced the more lesions he detects.

CONCLUSION: Along with the radiologist ability to detect lesions based on his level of experience, the OFSEP optimized 3DFLAIR can significantly improve infratentorial lesion detection in MS compared to 2DT2/PD. This is important in MS follow-up that takes into account new lesions number to adapt patients' treatment.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Hannoun S, Heidelberg D, Hourani R, et al. Diagnostic value of 3DFLAIR in clinical practice for the detection of infratentorial lesions in multiple sclerosis in regard to dual echo T2 sequences. Eur J Radiol. 2018. PMID: 29685528. doi:10.1016/j.ejrad.2018.03.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。