文献速递神经MR

脑胶质瘤交叉性小脑失联络的病理相关因素:灌注、扩散与结构MR成像联合研究

Pathological factors contributing to crossed cerebellar diaschisis in cerebral gliomas: a study combining perfusion, diffusion, and structural MR imaging.
PubMed 文献 · Neuroradiology · 2018-04-17

本研究纳入33例术前脑胶质瘤患者和33例健康对照,行动脉自旋标记、扩散张量成像和高分辨率T1加权成像,评估小脑血流量不对称指数与临床变量及扩散张量参数的相关性。患者肿瘤对侧小脑半球血流量降低、小脑血流量不对称增加(均P<0.05);高级别胶质瘤交叉性小脑失联络水平高于低级别(P<0.05);交叉性小脑失联络水平与幕上病灶大小负相关、与大脑纤维各向异性分数不对称正相关(均P<0.05)。

要点

  • 脑胶质瘤患者肿瘤对侧小脑半球血流量降低、小脑血流量不对称增加(均P<0.05)。
  • 高级别胶质瘤的交叉性小脑失联络水平高于低级别胶质瘤(P<0.05)。
  • 交叉性小脑失联络水平与幕上病灶大小负相关、与大脑纤维各向异性分数不对称正相关(均P<0.05)。

核心结论

  • 脑胶质瘤的交叉性小脑失联络与肿瘤组织学级别、病灶大小及肿瘤同侧大脑半球白质损伤特异性相关;观察交叉性小脑失联络可能有助于脑胶质瘤的分级诊断。

研究设计与样本

  • 术前脑胶质瘤患者33例与健康对照33例,行动脉自旋标记、扩散张量成像和高分辨率T1加权成像,分别估计脑血流量、白质完整性和病灶体积。

关键影像表现/征象

  • 患者肿瘤对侧小脑半球脑血流量降低,小脑脑血流量不对称增加(均P<0.05)。
  • 高级别胶质瘤的交叉性小脑失联络水平高于低级别胶质瘤(P<0.05)。
  • 交叉性小脑失联络水平与幕上病灶大小呈负相关(P<0.05)。
  • 交叉性小脑失联络水平与大脑纤维各向异性分数不对称呈正相关(P<0.05)。

诊断标准与关键数值

  • 以小脑脑血流量不对称指数评估交叉性小脑失联络水平。
  • 扩散张量成像参数包括皮质-脑桥-小脑通路及跨大脑半球纤维的各向异性分数和纤维数量。

临床应用与阅片要点

  • 观察小脑脑血流量不对称有助于提示幕上胶质瘤对侧小脑半球的交叉性小脑失联络。
  • 高级别胶质瘤的交叉性小脑失联络水平高于低级别胶质瘤(P<0.05)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate imaging features of crossed cerebellar diaschisis (CCD) in cerebral gliomas, and its underlying pathophysiological mechanisms.

METHODS: Thirty-three pre-surgical patients with cerebral gliomas and 33 healthy controls underwent arterial spin-labeling, diffusion tensor imaging, and high-resolution T1-weighted imaging using MRI, in order to estimate cerebral blood flow (CBF), white matter integrity, and lesion volume, respectively. Asymmetry indices of CBF in the cerebellum were used for evaluating the level of CCD in the patients. These indices were correlated with clinical variables (lesion size and position, tumor histological grade, and CBF asymmetry) and diffusion tensor imaging parameters (fractional anisotropy and number of fibers in the cortico-ponto-cerebellar pathway and across the cerebral hemispheres), respectively.

RESULTS: The patients showed decreased CBF in the cerebellar hemisphere contralateral to the supratentorial tumor, and increased CBF asymmetry in the cerebellum (both P < 0.05). CCD levels in high-grade gliomas were higher than those of low-grade gliomas (P < 0.05). CCD levels were negatively correlated with the size of the supratentorial lesions, and positively correlated with FA asymmetry in the cerebral fibers (both P < 0.05).

CONCLUSIONS: CCD in cerebral gliomas was specifically associated with tumor histological grade, lesion size, and white matter impairments in the hemisphere ipsilateral to the tumor. The findings implicated that observing CCD might have potential for assisting grading diagnosis of cerebral gliomas.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Liu X, Li J, Xu Q, et al. Pathological factors contributing to crossed cerebellar diaschisis in cerebral gliomas: a study combining perfusion, diffusion, and structural MR imaging. Neuroradiology. 2018. PMID: 29666881. doi:10.1007/s00234-018-2015-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。