多期肾双能CT虚拟平扫图像中肾实质衰减值:与标准平扫CT的比较
各期虚拟平扫与标准平扫平均衰减差值≤4 HU,肾实质期虚拟平扫与标准平扫最接近,去除标准平扫平均可降低辐射剂量12.3%±0.9%。
要点
- 各期虚拟平扫与标准平扫肾实质平均衰减差值均≤4 HU。
- 肾实质期虚拟平扫与标准平扫的肾皮质和髓质衰减最接近。
- 去除标准平扫平均可降低辐射剂量12.3%±0.9%。
核心结论
- 多期肾双能CT生成的虚拟平扫图像与标准平扫图像相似,肾实质期虚拟平扫较其他期相与标准平扫更接近。
研究设计与样本
- 回顾性研究,纳入29例男性和16例女性(平均年龄61±13岁,范围37-89岁),行四期动态肾双能CT(100/Sn140 kVp),包括平扫、皮髓质期、肾实质期和排泄期,从后三期生成虚拟平扫。
关键影像表现/征象
- 标准平扫肾皮质和髓质平均衰减分别为33.2±4.4 HU和34.2±4.8 HU。
- 皮髓质期虚拟平扫肾皮质和髓质平均衰减分别为33.6±7.6 HU和31.1±8.3 HU。
- 肾实质期虚拟平扫肾皮质和髓质平均衰减分别为34.8±8.6 HU和35.6±8.5 HU。
- 排泄期虚拟平扫肾皮质和髓质平均衰减分别为31.5±7.6 HU和32.4±7.5 HU,并可见集合系统碘减影不充分。
诊断标准与关键数值
- 标准平扫与各期虚拟平扫平均衰减差值≤4 HU。
- 皮髓质期虚拟平扫中肾皮质衰减高于髓质(p<0.05),髓质衰减显著低于标准平扫(p<0.01)。
- 肾实质期虚拟平扫中肾皮质衰减高于标准平扫(p<0.05)。
- 排泄期虚拟平扫中肾皮质和髓质衰减均低于标准平扫(p<0.05)。
- 图像噪声在标准平扫中显著更大(p<0.001)。
临床应用与阅片要点
- 肾实质期虚拟平扫在肾实质衰减上与标准平扫最接近,阅片时可优先参考该期相生成的虚拟平扫。
- 排泄期虚拟平扫存在集合系统碘减影不充分,判读时需注意。
- 去除标准平扫平均可降低辐射剂量12.3%±0.9%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare the renal parenchyma attenuation of virtual noncontrast (VNC) images derived from multiphase renal dual-energy computed tomography (DECT) with standard noncontrast (SNC) images, and to determine the optimum phase for VNC images.
MATERIALS AND METHODS: Twenty-nine men and 16 women (mean age, 61 ± 13 years; range, 37-89 years) underwent dynamic renal DECT (100/Sn140 kVp) were included in this institutional review board-approved retrospective study. There were four phases of the scan, which included noncontrast, corticomedullary (CMP), nephrographic (NP), and excretory phases (EP). The VNC images was generated from CMP, NP and EP. CT numbers of SNC images and VNC images of each phases were measured in the renal cortex and medulla. Mean standard deviation of subcutaneous fat was measured as image noise on SNC and VNC images. Radiation dose was recorded and potential radiation dose reduction was estimated. Results were tested for statistical significance using the unpaired t-test and agreement using Bland-Altman plot analysis.
RESULTS: The difference in mean attenuation between SNC and each phase of VNC images were ≤4 HU. The mean attenuation of renal cortex and medulla was 33.2 ± 4.4 HU, and 34.2 ± 4.8 HU in SNC, 33.6 ± 7.6 HU and 31.1 ± 8.3 HU in VNC of CMP, 34.8 ± 8.6 HU and 35.6 ± 8.5 HU in VNC of NP, 31.5 ± 7.6 HU and 32.4 ± 7.5 HU in VNC of EP. In VNC of CMP, the attenuation of the cortex was higher than the medulla (p < 0.05), and the attenuation of medulla was significant lower than that of SNC (p < 0.01). In VNC of NP, the attenuation of renal cortex was higher than SNC (p < 0.05). In VNC of EP, the attenuation of cortex and medulla were lower than SNC (p < 0.05), and inadequate iodine subtraction in collecting system was noted. Image noise was significantly greater in SNC (p < 0.001). Mean radiation dose reduction achievable by removing the SNC was 12.3% ± 0.9%.
CONCLUSIONS: VNC images from multiphase renal DECT were similar to SNC images. Using the nephrographic phase can gives more comparable VNC images to SNC images in renal parenchyma than other phases.
引用
- Lin YM, Chiou YY, Wu MH, et al. Attenuation values of renal parenchyma in virtual noncontrast images acquired from multiphase renal dual-energy CT: Comparison with standard noncontrast CT. Eur J Radiol. 2018. PMID: 29571782. doi:10.1016/j.ejrad.2018.02.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。