双能量CT与单能量CT在CT肺动脉造影中对DNA双链断裂影响的比较
62例患者行双源双能量CT肺动脉造影(第1组21例、第2组20例)或单能量CT肺动脉造影(第3组21例),比较淋巴细胞DNA双链断裂。三组检查后5分钟每个淋巴细胞的超额DSB灶均增多,但组间超额DSB灶/细胞及超额DSB百分比无差异(第1组23%、第2组24%、第3组20%,P=.932)。结论:双源双能量CT方案不增加估计辐射剂量,也不导致更高的DNA双链断裂发生率。
要点
- 双能量与单能量CT肺动脉造影后5分钟淋巴细胞超额DSB灶均增多(各组P≤.006)。
- 三组超额DSB灶/细胞及超额DSB百分比无差异(23% vs 24% vs 20%,P=.932)。
- 第1组CTDIvol、DLP及器官辐射剂量均为三组中最低(均P<.001)。
核心结论
- 双源和单源CT肺动脉造影后DSB均增加,双源双能量CT方案不增加估计辐射剂量,也不导致更高的DNA双链断裂发生率。
研究设计与样本
- 研究论文,62例患者,分为双能量CT肺动脉造影第1组(n=21,80/Sn140 kVp,89/38 mAs)、第2组(n=20,100/Sn140 kVp,89/76 mAs)和单能量CT肺动脉造影第3组(n=21,120 kVp,110 mAs),于检查前及检查后5分钟采血,用荧光显微镜评估DSB,Kruskal-Wallis检验比较组间DSB水平,ANOVA比较CTDIvol、DLP及器官辐射剂量。
诊断标准与关键数值
- 三组检查后5分钟每个淋巴细胞的超额DSB灶均增多(第1组P=.001;第2组P=.001;第3组P=.006)。
- 组间超额DSB灶/细胞及超额DSB百分比无差异(第1组23%、第2组24%、第3组20%,P=.932)。
- 第1组CTDIvol、DLP及器官辐射剂量为三组中最低(均P<.001)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the effect of dual-source dual-energy CT versus single-energy CT on DNA double-strand breaks (DSBs) in blood lymphocytes at CT pulmonary angiography (CTPA).
METHODS AND MATERIALS: Sixty-two patients underwent either dual-energy CTPA (Group 1: n = 21, 80/Sn140 kVp, 89/38 mAs; Group 2: n = 20, 100/Sn140 kVp, 89/76 mAs) or single-energy CTPA (Group 3: n = 21, 120 kVp, 110 mAs). Blood samples were obtained before and 5 min after CTPA. DSBs were assessed with fluorescence microscopy and Kruskal-Walls tests were used to compare DSBs levels among groups. Volume CT dose index (CTDIvol), dose length product (DLP) and organ radiation dose were compared using ANOVA.
RESULTS: There were increased excess DSB foci per lymphocyte 5 min after CTPA examinations in three groups (Group 1: P = .001; Group 2: P = .001; Group 3: P = .006). There were no differences among groups regarding excess DSB foci/cell and percentage of excess DSBs (Group 1, 23%; Group 2, 24%; Group 3, 20%; P = .932). CTDIvol, DLP and organ radiation dose in Group 1 were the lowest among the groups (all P < .001).
CONCLUSION: DSB is increased following dual-source and single-source CTPA, while dual-source dual-energy CT protocols do not increase the estimated radiation dose and also do not result in a higher incidence of DNA DSBs in patients undergoing CTPA.
引用
- Tao SM, Li X, Schoepf UJ, et al. Comparison of the effect of radiation exposure from dual-energy CT versus single-energy CT on double-strand breaks at CT pulmonary angiography. Eur J Radiol. 2018. PMID: 29571808. doi:10.1016/j.ejrad.2018.02.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。