文献速递腹部外周血管泌尿生殖CT

使用多期CT协议对自体肾进行动态CTA——显著降低对比剂用量的潜力

Dynamic CTA in Native Kidneys Using a Multiphase CT Protocol-Potential of Significant Reduction of Contrast Medium.
PubMed 文献 · Acad Radiol · 2018-03-12

本研究评估优化肾多期CT血管成像(MP-CTA)方案减少对比剂用量的效果:30例患者采用30 mL对比剂行12期MP-CTA,与标准肾CTA(80 mL)相比,动脉强化显著更高(主动脉503±91 HU vs 396±90 HU,P < .001),图像质量良好,平均有效辐射剂量9 mSv。

要点

  • MP-CTA使用30 mL对比剂即可获得主动脉503±91 HU、肾动脉450±73 HU/456±72 HU的高强化。
  • 与标准肾CTA(80 mL)相比,MP-CTA动脉强化显著更高(P < .001)。
  • MP-CTA肾动脉图像质量评分1.5±0.6、肾静脉1.7±0.6(1-4级,1为最佳)。

核心结论

  • 与标准肾CTA相比,肾MP-CTA能显著降低对比剂用量,同时提供显著更高的动脉强化。

研究设计与样本

  • 30例患者行肾MP-CTA(12期,每3.5秒一期,80 kV/120 mAs),使用30 mL对比剂;结果与标准肾CTA(80 mL)比较;定量测量血管衰减、图像噪声和对比噪声比,定性评估血管显示、皮质分化和运动伪影(1-4级,1为最佳),并记录平均有效辐射剂量。

诊断标准与关键数值

  • MP-CTA主动脉衰减503±91 HU,肾动脉450±73 HU/456±72 HU,图像噪声13.7±1.5,对比噪声比34.2±10.2,肾静脉286±43 HU/282±42 HU。
  • 标准肾CTA主动脉衰减396±90 HU,肾动脉331±74 HU/333±80 HU,MP-CTA动脉强化显著更高(P < .001)。
  • MP-CTA肾动脉图像质量评分1.5±0.6,肾静脉1.7±0.6,皮质分化1.8±0.8,运动伪影1.6±0.8(1-4级,1为最佳)。
  • MP-CTA平均有效辐射剂量9 mSv。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVE: The objective of this study was to assess an optimized renal multiphase computed tomography angiography (MP-CTA) protocol regarding reduction of contrast volume.

MATERIALS AND METHODS: Thirty patients underwent MP-CTA (12 phases, every 3.5 seconds, 80 kV/120 mAs) using 30 mL of contrast medium. The quality of MP-CTA was assessed quantitatively measuring vessel attenuation, image noise, and contrast-to-noise ratio. MP-CTA was evaluated qualitatively regarding depiction of vessels, cortex differentiation, and motion artifacts (grades 1-4, 1 = best). Mean effective radiation dose was registered. Results were compared to standard renal computed tomography angiography (CTA) (80 mL). Student t test was applied, if variables followed normal distribution. For other variables, nonparametric Mann-Whitney U test was used.

RESULTS: All acquisitions were successfully performed, and no patient had to be excluded from the study. MP-CTA enabled high attenuation (aorta: 503 ± 91 HU, renal arteries: 450 ± 73 HU/456 ± 72 HU) at adequate image noise (13.7 ± 1.5) and good contrast-to-noise ratio (34.2 ± 10.2). Good attenuation of renal veins was observed (286 ± 43 HU/282 ± 42 HU). Arterial enhancement was significantly higher compared to renal CTA (aorta: 396 ± 90 HU, renal arteries: 331 ± 74 HU/333 ± 80 HU; P < .001). MP-CTA protocol enabled good image quality of renal arteries (1.5 ± 0.6) and veins (1.7 ± 0.6). Cortex differentiation and motion artifacts were ranked 1.8 ± 0.8 and 1.6 ± 0.8. The mean effective radiation dose was 9 mSv (MP-CTA).

CONCLUSIONS: Compared to standard renal CTA, the renal MP-CTA enabled the significant reduction of contrast volume and simultaneously provided a significantly higher arterial attenuation.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Braunagel M, Ortner F, Schönermarck U, et al. Dynamic CTA in Native Kidneys Using a Multiphase CT Protocol-Potential of Significant Reduction of Contrast Medium. Acad Radiol. 2018. PMID: 29545025. doi:10.1016/j.acra.2017.11.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。