基于C臂锥形束CT的三维深度学习血管造影(3D-DLA)
研究开发了一种深度学习血管造影方法,从单次增强C臂锥形束CT采集生成三维脑血管造影,以减少图像伪影和辐射剂量。研究使用105例三维旋转血管造影数据,训练深度卷积神经网络将每个体素分类为血管、骨和软组织,并在测试集中评估。结果显示血管分类准确率达98.7%(95%CI 98.3%-99.1%),且无残留骨信号,而三维旋转血管造影中37%(23/62)存在骨信号。
要点
- 深度学习血管造影可从单次增强C臂锥形束CT生成三维脑血管造影,无需掩模。
- 测试集血管分类准确率为98.7%(95%CI 98.3%-99.1%)。
- 除耳囊和鼻腔小区域外,测试病例无残留骨信号,而37%(23/62)的三维旋转血管造影存在骨信号。
核心结论
- 深度学习血管造影准确重建了三维旋转血管造影的血管解剖,无需掩模,减少了扫描间运动引起的配准伪影,并降低了获得临床有用三维旋转血管造影所需的辐射暴露。
关键影像表现/征象
- 测试数据集血管分类准确度和95%CI为98.7%(98.3%-99.1%);除耳囊和鼻腔小区域外,任何三维深度学习血管造影测试病例均未观察到骨结构残留信号,而三维旋转血管造影中37%(23/62)存在骨信号。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Deep learning is a branch of artificial intelligence that has demonstrated unprecedented performance in many medical imaging applications. Our purpose was to develop a deep learning angiography method to generate 3D cerebral angiograms from a single contrast-enhanced C-arm conebeam CT acquisition in order to reduce image artifacts and radiation dose.
MATERIALS AND METHODS: A set of 105 3D rotational angiography examinations were randomly selected from an internal data base. All were acquired using a clinical system in conjunction with a standard injection protocol. More than 150 million labeled voxels from 35 subjects were used for training. A deep convolutional neural network was trained to classify each image voxel into 3 tissue types (vasculature, bone, and soft tissue). The trained deep learning angiography model was then applied for tissue classification into a validation cohort of 8 subjects and a final testing cohort of the remaining 62 subjects. The final vasculature tissue class was used to generate the 3D deep learning angiography images. To quantify the generalization error of the trained model, we calculated the accuracy, sensitivity, precision, and Dice similarity coefficients for vasculature classification in relevant anatomy. The 3D deep learning angiography and clinical 3D rotational angiography images were subjected to a qualitative assessment for the presence of intersweep motion artifacts.
RESULTS: Vasculature classification accuracy and 95% CI in the testing dataset were 98.7% (98.3%-99.1%). No residual signal from osseous structures was observed for any 3D deep learning angiography testing cases except for small regions in the otic capsule and nasal cavity compared with 37% (23/62) of the 3D rotational angiographies.
CONCLUSIONS: Deep learning angiography accurately recreated the vascular anatomy of the 3D rotational angiography reconstructions without a mask. Deep learning angiography reduced misregistration artifacts induced by intersweep motion, and it reduced radiation exposure required to obtain clinically useful 3D rotational angiography.
引用
- Montoya JC, Li Y, Strother C, et al. 3D Deep Learning Angiography (3D-DLA) from C-arm Conebeam CT. AJNR Am J Neuroradiol. 2018. PMID: 29567655. doi:10.3174/ajnr.A5597
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。