利用时间分辨对比剂动态成像(TRICKS)序列的MRI评估外周血管异常
前瞻性纳入66例上肢或下肢血管异常患者(23例儿童、43例成人,平均年龄26岁),在1.5T全身MR系统上行TRICKS序列检查,两名独立阅片者进行分类并评估图像质量,其中11例与数字减影血管造影对照。基于TRICKS,31例分类为高流量血管畸形、29例为低流量血管病变、6例为血管瘤;两名观察者间图像质量评价与血管异常分类无显著差异,DSA证实了TRICKS所提供的血管异常特征。
要点
- TRICKS序列可提供时间信息,帮助正确评估血管异常各组分。
- 66例中基于TRICKS分类为高流量血管畸形31例、低流量血管病变29例、血管瘤6例。
- 11例与DSA对照,中等、良好或优秀质量的TRICKS图像所示血管异常特征均获DSA证实。
核心结论
- TRICKS序列使放射科医生能获取有用的时间信息以正确评估血管异常组分,在传统MR序列所提供数据之外增加信息,尤其在动静脉畸形时;因此,在儿童和成人中,TRICKS可作为额外的初始诊断工具,以正确分类这些病变并评估是否需要治疗及选择何种治疗。
研究设计与样本
- 前瞻性研究,纳入66例上肢或下肢血管异常患者(23例儿童、43例成人,平均年龄26岁),全部在1.5T全身MR系统上行TRICKS序列检查,由两名独立阅片者在增强前和增强后MR序列上分类疑似血管异常并评估TRICKS整体图像质量,其中11例评估TRICKS序列与数字减影血管造影的诊断性能可比性。
关键影像表现/征象
- 基于TRICKS,31例血管异常分类为高流量血管畸形,29例分类为低流量血管病变,6例分类为血管瘤。
诊断标准与关键数值
- 两名观察者间图像质量评价与血管异常分类无显著差异。
- 11例中,中等、良好或优秀质量的TRICKS图像所提供的血管异常特征均经数字减影血管造影证实。
临床应用与阅片要点
- TRICKS序列可提供时间信息,帮助在常规MR序列之外正确评估血管异常组分。
- 作者认为TRICKS可作为儿童和成人血管异常的额外初始诊断工具,用于正确分类病变并评估是否需要治疗及选择何种治疗。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: We describe the use of time-resolved imaging of contrast kinetics (TRICKS) sequence in the diagnosis of Peripheral Vascular Anomalies. In case of suspected vascular malformations time-resolved MR angiography might add important information for therapeutic decisions and follow-up.
OBJECTIVE: The objective of our study was to assess the usefulness and diagnostic performance of time-resolved imaging of contrast kinetics sequence in the evaluation of peripheral vascular anomalies.
SUBJECTS AND METHODS: Sixty-six patients (23 pediatric, 43 adult; mean age 26) affected by upper or lower limb vascular anomalies and studied using time-resolved imaging of contrast kinetics sequence were prospectively evaluated. All studies were performed on a 1.5-T whole-body MR system. Two independent readers tried to categorized the suspected vascular anomalies in pre-contrast and post-contrast MR sequences and assessed the overall TRICKS image quality. In 11 patients, the diagnostic performance comparability between TRICKS sequence and digital subtraction angiography was evaluated.
RESULTS: On the basis of time-resolved imaging of contrast kinetics, 31 of the vascular anomalies were classified as high-flow vascular malformations, 29 as low-flow vascular lesions and 6 as hemangiomas. There was no significant difference in image quality evaluation and vascular anomaly classification between the two observers. The vascular anomalies characteristics provided by moderate, good or excellent quality TRICKS images were confirmed by digital subtraction angiography.
CONCLUSION: Time-resolved imaging of contrast kinetics sequence let the radiologist to acquire useful temporal information to correctly evaluate vascular anomalies components, adding more data to those provided by conventional MR sequences, especially in case of arteriovenous malformation. Therefore, both in pediatric and adult population, TRICKS could be used as an additional initial diagnostic tool to rightly classify these lesions and evaluate if a treatment is needed and which.
引用
- Schicchi N, Tagliati C, Agliata G, et al. MRI evaluation of peripheral vascular anomalies using time-resolved imaging of contrast kinetics (TRICKS) sequence. Radiol Med. 2018. PMID: 29569217. doi:10.1007/s11547-018-0875-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。