文献速递神经介入DSA

动脉瘤栓塞过程中支架尖端嵌入颈内动脉分支患者的长期结局

Long-Term Outcomes of Patients with Stent Tips Embedded into Internal Carotid Artery Branches during Aneurysm Coiling.
PubMed 文献 · AJNR Am J Neuroradiol · 2018-03-08

本研究在2003年11月至2014年11月间接受支架辅助栓塞治疗的35例未破裂颈内动脉动脉瘤患者中,识别出支架尖端无意嵌入颈内动脉分支的病例,分析其临床与血管造影结局。随访38.6±17.9个月期间无新发神经功能缺损、出血或血栓栓塞事件,最终造影(平均32.7±18.0个月)显示所有受累分支血流通畅、无严重管腔狭窄。作者认为支架尖端嵌入颈内动脉分支未伴随重大不良事件。

要点

  • 支架尖端带不透射线标记,术后可识别其是否嵌入颈内动脉分支。
  • 最常累及的后交通动脉(26例,74.3%),其次为脉络膜前动脉(8例,22.9%)和眼动脉(1例,2.9%)。
  • 随访期间嵌入支架尖端的颈内动脉分支均保持血流通畅,无严重管腔狭窄。

核心结论

  • 作者经验中,支架辅助栓塞时支架尖端嵌入颈内动脉分支未伴随任何重大不良事件。

研究设计与样本

  • 回顾性分析2003年11月至2014年11月间35例接受支架辅助栓塞治疗的未破裂颈内动脉动脉瘤患者,识别支架尖端嵌入颈内动脉分支的病例并分析临床与血管造影结局。

关键影像表现/征象

  • 35例动脉瘤中多数为颈内动脉旁结节段动脉瘤(n=30)。
  • 最常累及的颈内动脉分支为后交通动脉(26例,74.3%),其次为脉络膜前动脉(8例,22.9%)和眼动脉(1例,2.9%)。

诊断标准与关键数值

  • 最终随访造影(平均32.7±18.0个月)显示所有嵌入支架尖端的颈内动脉分支血流通畅,无严重管腔狭窄。
  • 随访期(38.6±17.9个月)内无新发神经功能缺损,无出血性或缺血性血栓栓塞事件。

临床应用与阅片要点

  • 支架尖端带不透射线标记,术后影像可识别其是否嵌入颈内动脉分支。
  • 作者经验中,支架尖端嵌入颈内动脉分支未伴随重大不良事件。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: During stent-assisted coiling of ICA aneurysms, stent tips are sometimes unintentionally embedded into ICA branches. Stent tips can be visualized because they have radiopaque markers. Concerns regarding stent tip misplacement include risks of artery perforation and occlusion. The aim of this study was to evaluate the long-term outcomes of ICA branches with embedded stent tips.

MATERIALS AND METHODS: ICA branches with embedded stent tips were identified among 35 patients with unruptured ICA aneurysms treated with stent-assisted coiling between November 2003 and November 2014. Patient clinical and angiographic outcomes associated with the embedded stent tip were analyzed.

RESULTS: Most of the 35 studied aneurysms were paraclinoid ICA aneurysms (n = 30). The most commonly involved ICA branch was the posterior communicating artery (26 patients, 74.3%), followed by the anterior choroidal artery (8 patients, 22.9%) and ophthalmic artery (1 patient, 2.9%). During the follow-up period (38.6 ± 17.9 months), no new neurologic deficits developed. Neither hemorrhagic nor thromboembolic events occurred. Angiography was performed during the final follow-up evaluation at a mean of 32.7 ± 18.0 months, and all ICA branches with embedded stent tips showed patent blood flow without severe luminal narrowing.

CONCLUSIONS: In our experience, placement of a stent tip into ICA branches during stent-assisted coiling was not associated with any major adverse events.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Ban SP, Kwon OK, Lee SU, et al. Long-Term Outcomes of Patients with Stent Tips Embedded into Internal Carotid Artery Branches during Aneurysm Coiling. AJNR Am J Neuroradiol. 2018. PMID: 29519788. doi:10.3174/ajnr.A5583

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。