文献速递骨肌MR

7 T 与 3 T 成像评估膝关节低级别半月板及软骨损伤的对比:与关节镜结果对照

Assessment of Low-Grade Meniscal and Cartilage Damage of the Knee at 7 T: A Comparison to 3 T Imaging With Arthroscopic Correlation.
PubMed 文献 · Invest Radiol · 2018-01-01

前瞻性纳入 41 例疑似半月板损伤或轻度骨关节炎患者,同一患者连续接受 7 T 与常规临床 3 T MRI,两者均为 PD 加权成像且 7 T 分辨率提高逾一倍;由 3 名不同经验阅片者按改良全器官 MRI 评分和 ICRS 评分盲法阅片,12 例以关节镜报告为参考标准。结果 7 T 累积诊断评分显著更接近参考标准(P < 0.001),全部 41 例中 7 T 对软骨和半月板损伤的累积评分均显著更高(均 P < 0.001),阅片者间变异无差异,采集时间几乎相同。

要点

  • 7 T PD 加权 TSE 序列对膝关节软骨和半月板损伤的诊断准确度似乎显著高于 3 T。
  • 全部 41 例中 7 T 对软骨与半月板损伤的累积评分均显著更高(均 P < 0.001)。
  • 7 T 与 3 T 的阅片者间变异无差异,且采集时间几乎相同。

核心结论

  • 7 T 超高清场 MRI 采用 PD 加权 TSE 序列对膝关节软骨和半月板损伤的形态学成像,诊断准确度似乎显著高于 3 T,可在采集时间相同的情况下利用 7 T 更高分辨率完成检查。

研究设计与样本

  • 前瞻性研究,41 例疑似半月板损伤或轻度骨关节炎(Kellgren-Lawrence 评分 0-2)患者连续接受 7 T 与常规临床 3 T MRI;两种场强方案均为 PD 加权成像,7 T 分辨率提高逾一倍;3 名骨肌 MRI 经验分别为 3 年、6 年、10 年的阅片者按改良全器官 MRI 评分和 International Cartilage Repair Society 评分盲法阅片;12 例以关节镜报告为参考标准;采用多因素混合模型分析。

诊断标准与关键数值

  • 在有参考标准的患者中,7 T 平均累积诊断评分显著更接近参考标准(P < 0.001)。
  • 全部 41 例中 7 T 对软骨损伤的累积评分显著更高(P < 0.001)。
  • 全部 41 例中 7 T 对半月板损伤的累积评分显著更高(P < 0.001)。
  • 7 T 与 3 T 之间阅片者间变异无差异。
  • 7 T 与 3 T 的成像采集时间几乎相同。

局限性

  • 关节镜参考标准仅对 12 例患者可得。
  • 结论措辞为 seemed to have,提示为观察性比较结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to compare the assessment of low-grade meniscal tears and cartilage damage in ultrahigh-field magnetic resonance imaging (MRI) at 7 T to routine clinical MRI at 3 T.

MATERIALS AND METHODS: This study was approved by the local ethics committee, and written informed consent was obtained from each patient. Forty-one patients with suspected meniscal damage or mild osteoarthritis (Kellgren-Lawrence score, 0-2) received 7 T as well as routine clinical 3 T consecutively. The imaging protocol at both field strengths consisted of PD-weighted imaging with more than doubled resolution at 7 T. Images were read blinded regarding field strength and patient characteristics by 3 readers with different experience in musculoskeletal MRI (3 years, 6 years, and 10 years) according to a modified whole-organ MRI score of the knee in osteoarthritis and the Score of the International Cartilage Repair Society. Arthroscopic reports as a criterion standard were available for 12 patients. A multifactorial mixed model analysis was performed.

RESULTS: The mean cumulated diagnostic score at 7 T was significantly closer to the criterion standard compared with 3 T in patients where criterion standard was available (P < 0.001). In all 41 patients, the damages were rated more severely at 7 T reflected by a mean higher cumulative score in cartilage (P < 0.001) and in the meniscus (P < 0.001). No difference in interreader variability between 3 T and 7 T was observed. Imaging acquisition time was nearly identical.

CONCLUSIONS: Morphologic imaging of cartilage and meniscal damage of the knee in ultrahigh-field MRI at 7 T with PD-weighted TSE sequences seemed to have a significantly higher diagnostic accuracy than 3 T and can be performed with equal acquisition times while exploiting higher resolution of 7 T.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Friebe B, Richter M, Penzlin S, et al. Assessment of Low-Grade Meniscal and Cartilage Damage of the Knee at 7 T: A Comparison to 3 T Imaging With Arthroscopic Correlation. Invest Radiol. 2018. PMID: 29521888. doi:10.1097/RLI.0000000000000456

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。