文献速递骨肌US

低强度脉冲超声预防大鼠制动膝关节模型关节僵硬的效果

Effects of Low-Intensity Pulsed Ultrasound for Preventing Joint Stiffness in Immobilized Knee Model in Rats.
PubMed 文献 · Ultrasound Med Biol · 2018-03-21

本研究在大鼠单侧膝关节制动模型中评估低强度脉冲超声(LIPUS)预防关节僵硬的作用。LIPUS组(每时段n=6)每日20分钟、每周5天接受1.5 MHz、1.0 kHz重复周期、200 µs burst宽度、30 mW/cm²功率输出的LIPUS至2、4或6周终点,对照组仅接受全身麻醉。LIPUS对关节僵硬有预防作用,减少制动后的粘连、纤维化和炎症及缺氧反应。

要点

  • LIPUS可减少制动关节的粘连、纤维化和炎症及缺氧反应。
  • LIPUS对关节僵硬有预防作用,表现为关节角度等变量改善。
  • 动物实验证据,尚需进一步研究验证临床转化。

核心结论

  • LIPUS对关节僵硬有预防作用,减少制动后的粘连、纤维化和炎症及缺氧反应。

研究设计与样本

  • 动物实验:大鼠单侧膝关节制动模型,两组(每时段每组n=6),LIPUS组使用现有LIPUS装置(1.5 MHz频率、1.0 kHz重复周期、200 µs burst宽度、30 mW/cm²功率输出)每日20分钟、每周5天至2、4或6周终点,对照组仅全身麻醉;比较关节角度、组织学、组织形态计量学和免疫组化分析、定量逆转录聚合酶链反应及组织弹性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The purpose of this study was to examine the effect of low-intensity pulsed ultrasound (LIPUS) in preventing joint stiffness. Unilateral knee joints were immobilized in two groups of rats (n = 6/period/group). Under general anesthesia, the immobilized knee joints were exposed to LIPUS for 20 min/d, 5 d/wk, using an existing LIPUS device (LIPUS group, 1.5-MHz frequency, 1.0-kHz repetition cycle, 200-µs burst width and 30-mW/cm2 power output) until endpoints (2, 4 or 6 wk). In the control group, general anesthesia alone was administered in the same manner as in the other group. The variables compared between the groups included joint angles; histologic, histomorphometric and immunohistochemical analyses; quantitative reverse transcription polymerase chain reactions; and tissue elasticity. LIPUS had a preventive effect on joint stiffness, resulting in decreased adhesion, fibrosis and inflammation and hypoxic response after joint immobilization.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Itaya N, Yabe Y, Hagiwara Y, et al. Effects of Low-Intensity Pulsed Ultrasound for Preventing Joint Stiffness in Immobilized Knee Model in Rats. Ultrasound Med Biol. 2018. PMID: 29573888. doi:10.1016/j.ultrasmedbio.2018.02.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。