文献速递胸部腹部骨肌介入CT

CT引导活检中的辐射暴露:新型CT设备显著降低剂量

Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower doses.
PubMed 文献 · Eur Radiol · 2018-03-28

该回顾性多中心研究纳入2013至2016年间1219例胸部、腹部、脊柱及四肢CT引导介入活检,比较不同代CT设备的辐射剂量。结果显示较新CT设备(SOMATOM Definition AS+)各部位平均有效剂量均低于旧设备(Volume-Zoom或Emotion6),新型CT设备辐射剂量显著降低。

要点

  • 不同代CT设备辐射剂量差异明显,新型设备有效剂量更低。
  • 腹部活检有效剂量:SOMATOM Definition AS+ 9.3 mSv vs Volume-Zoom 13.9 mSv。
  • 胸部活检有效剂量:SOMATOM Definition AS+ 7.3 mSv vs Emotion6 11.4 mSv。

核心结论

  • 不同代CT设备行CT引导介入活检时,新型CT设备较旧设备辐射剂量显著降低。

研究设计与样本

  • 回顾性多中心研究,纳入2013至2016年1219例CT引导介入活检,使用SOMATOM Definition AS+、Volume-Zoom、Emotion6三种CT设备,按ICRP103采用蒙特卡罗模拟计算有效剂量和器官剂量。

诊断标准与关键数值

  • 腹部活检平均有效剂量:SOMATOM Definition AS+ 9.3 mSv vs Volume-Zoom 13.9 mSv。
  • 胸部活检平均有效剂量:SOMATOM Definition AS+ 7.3 mSv vs Emotion6 11.4 mSv。
  • 脊柱活检平均有效剂量:SOMATOM Definition AS+ 6.3 mSv vs Volume-Zoom 7.4 mSv。
  • 四肢活检平均有效剂量:SOMATOM Definition AS+ 4.3 mSv vs Volume-Zoom 10.8 mSv。

临床应用与阅片要点

  • 有效剂量、器官剂量和SSDE数据可用于识别接受较高辐射剂量的器官。
  • 对辐射剂量的详细了解可能有助于更好的个体风险分层。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To examine radiation dose levels of CT-guided interventional procedures of chest, abdomen, spine and extremities on different CT-scanner generations at a large multicentre institute.

MATERIALS AND METHODS: 1,219 CT-guided interventional biopsies of different organ regions ((A) abdomen (n=516), (B) chest (n=528), (C) spine (n=134) and (D) extremities (n=41)) on different CT-scanners ((I) SOMATOM-Definition-AS+, (II) Volume-Zoom, (III) Emotion6) were included from 2013-2016. Important CT-parameters and standard dose-descriptors were retrospectively examined. Additionally, effective dose and organ doses were calculated using Monte-Carlo simulation, following ICRP103.

RESULTS: Overall, radiation doses for CT interventions are highly dependent on CT-scanner generation: the newer the CT scanner, the lower the radiation dose imparted to patients. Mean effective doses for each of four procedures on available scanners are: (A) (I) 9.3mSv versus (II) 13.9mSv (B) (I) 7.3mSv versus (III) 11.4mSv (C) (I) 6.3mSv versus (II) 7.4mSv (D) (I) 4.3mSv versus (II) 10.8mSv. Standard dose descriptors [standard deviation (SD); CT dose indexvol (CTDIvol); dose-length product (DLPbody); size-specific dose estimate (SSDE)] were also compared.

CONCLUSION: Effective dose, organ doses and SSDE for various CT-guided interventional biopsies on different CT-scanner generations following recommendations of the ICRP103 are provided. New CT-scanner generations involve markedly lower radiation doses versus older devices.

KEY POINTS: • Effective dose, organ dose and SSDE are provided for CT-guided interventional examinations. • These data allow identifying organs at risk of higher radiation dose. • Detailed knowledge of radiation dose may contribute to a better individual risk-stratification. • New CT-scanner generations involve markedly lower radiation doses compared to older devices.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Guberina N, Forsting M, Ringelstein A, et al. Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower doses. Eur Radiol. 2018. PMID: 29594401. doi:10.1007/s00330-018-5350-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。