剪切波弹性成像评估健康成人假声带的可行性研究
前瞻性纳入10名健康成人,经甲状腺软骨水平经皮使用声辐射力脉冲成像测量双侧假声带剪切波速度(SWV),每侧在內收和外展状态下各测量5次并重复两次。假声带SWV在内收时显著高于外展时(P < .001),内收时女性显著高于男性(P < .001),左右侧及外展时男女间无显著差异(P > .05)。平均SWV指数为0.05(范围0.03-0.07),观察者内一致性的组内相关系数为0.89(P < .001)。剪切波弹性成像似乎可用于量化健康成人假声带的力学特性并评估其对称性。
要点
- 假声带SWV在内收时显著高于外展时(P < .001)。
- 内收时女性假声带SWV显著高于男性(P < .001)。
- 左右侧假声带SWV在内收或外展时均无显著差异(P > .05)。
核心结论
- 剪切波弹性成像似乎可用于量化健康成人假声带的力学特性并评估其对称性。
研究设计与样本
- 前瞻性可行性研究,纳入10名健康成人(5男5女),经甲状腺软骨水平经皮使用声辐射力脉冲成像测量双侧假声带SWV,每侧在内收和外展状态下各测量5次并重复两次,采用配对t检验比较,以组内相关系数评估观察者内一致性。
诊断标准与关键数值
- 假声带SWV在内收时显著高于外展时(P < .001)。
- 内收时女性假声带SWV显著高于男性(P < .001)。
- 左右侧假声带SWV在内收或外展时无显著差异(P > .05),外展时男女间无显著差异(P > .05)。
- 平均SWV指数为0.05(范围0.03-0.07)。
- 观察者内一致性的组内相关系数为0.89(P < .001)。
临床应用与阅片要点
- 作者认为剪切波弹性成像似乎可用于量化健康成人假声带的力学特性并评估其对称性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of the study was to investigate the feasibility of using ultrasound shear wave elastography to quantify mechanical properties and movement symmetry of false vocal folds positioned in adduction and abduction.
METHODS: We prospectively measured the shear wave velocity (SWV) within the bilateral false vocal folds in 10 healthy adults using acoustic radiation force impulse imaging. From a transcutaneous approach at the level of thyroid cartilage, 5 SWV measurements were obtained within each side of the false vocal folds twice in adduction and again in abduction for each participant. Configuration-related differences in the SWV within false vocal folds were compared between adduction and abduction, in addition to differences between the right and left false vocal folds and between men and women, by a paired t test. We developed an SWV index [(SWVgreater - SWVlesser )/SWVgreater ] to assess movement symmetry between the right and left false vocal folds. Intraobserver agreement on repeated measures was examined by the intraclass correlation coefficient.
RESULTS: The 10 participants included 5 men and 5 women. We observed that the SWV within false vocal folds was significantly higher in adduction than in abduction (P < .001). The SWV within false vocal folds in adduction was also significantly higher in women compared to men (P < .001). There was no significant difference in the SWV between the right and left false vocal folds in adduction or in abduction or between men and women in abduction (P > .05). The mean SWV index was 0.05 (range, 0.03-0.07). The intraclass correlation coefficient for intraobserver agreement was 0.89 (P < .001).
CONCLUSIONS: Shear wave elastography seems to be feasible to quantify mechanical properties and evaluate the symmetry of false vocal folds in healthy adults.
引用
- Gao J, Zhu Q, Xia CX, et al. Shear Wave Elastography to Assess False Vocal Folds in Healthy Adults: A Feasibility Study. J Ultrasound Med. 2018. PMID: 29574913. doi:10.1002/jum.14611