超声与计算机断层扫描诊断弥漫性甲状腺疾病的多中心比较研究
多中心回顾性纳入177例术前行甲状腺超声和颈部CT并接受甲状腺手术的患者,按四级分类法评估弥漫性甲状腺疾病,并与组织病理对照。CT和超声诊断弥漫性甲状腺疾病的AUC分别为0.893和0.866,敏感度84.4%和71.9%,特异度84.1%和91.2%;阅片者经验与诊断效能无统计学显著差异。作者认为超声和CT可能有助于检出偶然发现的弥漫性甲状腺疾病。
要点
- CT以≥2项弥漫性甲状腺疾病特征为阳性时AUC 0.893,敏感度84.4%、特异度84.1%。
- 超声以≥2项弥漫性甲状腺疾病特征为阳性时AUC 0.866,敏感度71.9%、特异度91.2%。
- 阅片者经验与诊断效能之间无统计学显著差异。
核心结论
- 超声和CT影像可能有助于检出偶然发现的弥漫性甲状腺疾病。
研究设计与样本
- 多中心回顾性研究,纳入2016年7月至12月4家参与机构中术前行甲状腺超声和颈部CT并随后接受甲状腺手术的177例患者。
关键影像表现/征象
- 超声分类:无弥漫性甲状腺疾病75例、不确定46例、可疑弥漫性甲状腺疾病28例、弥漫性甲状腺疾病28例。
- CT分类:无弥漫性甲状腺疾病71例、不确定34例、可疑弥漫性甲状腺疾病31例、弥漫性甲状腺疾病41例。
- 组织病理:正常甲状腺实质113例、桥本甲状腺炎23例、非桥本淋巴细胞性甲状腺炎36例、弥漫性增生5例。
诊断标准与关键数值
- 以≥2项超声或CT弥漫性甲状腺疾病特征(即分类为可疑弥漫性甲状腺疾病或弥漫性甲状腺疾病)为阳性,超声AUC 0.866,CT AUC 0.893。
- 超声诊断弥漫性甲状腺疾病的敏感度71.9%、特异度91.2%,CT敏感度84.4%、特异度84.1%。
临床应用与阅片要点
- 阅片者经验与诊断效能之间无统计学显著差异,提示不同经验水平的医师判读结果相近。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the diagnostic performance of ultrasonography (US) and computed tomography (CT) for diagnosing incidentally detected diffuse thyroid disease (DTD) in patients who underwent thyroid surgery using multicenter data.
METHODS: Between July and December 2016, a total of 177 patients who underwent preoperative thyroid US and neck CT, and subsequent thyroid surgery at 4 participating institutions, were reviewed. US and CT images in each case were retrospectively reviewed by a radiologist at each institution, and classified into one of the following four categories based on US and CT features: no DTD; indeterminate; suspicious for DTD; and DTD. The diagnostic accuracy of US and CT were calculated at each institution by comparison with histopathological results.
RESULTS: Respective US and CT classifications in the 177 patients were no DTD in 75 and 71, indeterminate in 46 and 34, suspicious for DTD in 28 and 31, and DTD in 28 and 41. Among the histopathological results, 113 patients had normal thyroid parenchyma, 23 had Hashimoto thyroiditis, 36 had non-Hashimoto lymphocytic thyroiditis, and 5 had diffuse hyperplasia. The presence of ≥ 2 US and CT features of DTD, which was classified as suspicious for DTD or DTD, had the largest area under the receiver operating characteristic curve (0.866 and 0.893, respectively), with sensitivity and specificity of 71.9 and 91.2% in US, and 84.4 and 84.1% in CT, respectively. However, there was no statistically significant difference between readers' experience and their diagnostic performance.
CONCLUSION: US and CT imaging may be helpful for detecting incidental DTD.
引用
- Kim DW, Lee YJ, Ahn HS, et al. Comparison of ultrasonography and computed tomography for diagnosing diffuse thyroid disease: a multicenter study. Radiol Med. 2018. PMID: 29525831. doi:10.1007/s11547-018-0872-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。