文献速递甲状腺与浅表US

联合推挤式超声剪切波弹性成像鉴别甲状腺结节良恶性:平面初步研究

Differentiation of Benign and Malignant Thyroid Nodules by Using Comb-push Ultrasound Shear Elastography: A Preliminary Two-plane View Study.
PubMed 文献 · Acad Radiol · 2018-03-21

本研究纳入2015年3月至2017年5月155例患者173个甲状腺结节,行纵向与横向两平面联合推挤式剪切波弹性成像,测量平均与最大弹性值。两平面平均Emean和Emax的AUC分别为92%和93%,cutoff分别为49.09 kPa和105.61 kPa,敏感度95.45%、特异度86.61%;纵向测量值显著高于横向,钙化与弹性值升高相关,血管成分或甲状腺肿与弹性值降低相关。

要点

  • 两平面平均Emean cutoff 49.09 kPa、Emax cutoff 105.61 kPa,AUC分别为92%和93%。
  • 纵向平面弹性测量值显著高于横向平面,阅片需注意探头方向影响。
  • 结节钙化与弹性值升高相关,血管成分或甲状腺肿与弹性值降低相关。

核心结论

  • 甲状腺结节弹性特性有望良好鉴别良恶性(P < .0001),但探头方向和钙化、血管成分、甲状腺肿等内部特征可能影响最终弹性测量值,需更大数量恶性结节研究进一步验证。

研究设计与样本

  • 前瞻性招募2015年3月至2017年5月155例患者(106女、49男,平均年龄57.48 ± 14.44岁)共173个甲状腺结节(平均大小24.89 ± 15.41 mm,范围5-68 mm),均计划行细针穿刺活检;于纵向和横向解剖平面行联合推挤式剪切波弹性成像,获取平均弹性值(Emean)和最大弹性值(Emax)。

关键影像表现/征象

  • 纵向平面弹性测量值在统计学上显著高于横向平面测量值。
  • 伴钙化的结节与弹性值升高相关。
  • 伴血管成分或位于增大的甲状腺(甲状腺肿)内的结节与较低弹性值相关。

诊断标准与关键数值

  • 两平面平均Emean:AUC 92%,cutoff 49.09 kPa。
  • 两平面平均Emax:AUC 93%,cutoff 105.61 kPa。
  • 两平面平均Emean和Emax参数:敏感度95.45%、特异度86.61%、阳性预测值0.58、阴性预测值0.99。

临床应用与阅片要点

  • 弹性测量需结合探头方向解读,纵向与横向平面测量值存在显著差异。
  • 判读弹性值时应考虑结节钙化、血管成分及甲状腺肿等可能影响测量值的因素。

局限性

  • 需更大数量恶性结节研究以进一步验证结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Low specificity of traditional ultrasound in differentiating benign from malignant thyroid nodules leads to a great number of unnecessary (ie, benign) fine-needle aspiration biopsies that causes a significant financial and physical burden to the patients. Ultrasound shear wave elastography is a technology capable of providing additional information related to the stiffness of tissues. In this study, quantitative stiffness values acquired by ultrasound shear wave elastography in two different imaging planes were evaluated for the prediction of malignancy in thyroid nodules. In addition, the association of elasticity measurements with sonographic characteristics of thyroid gland and nodules is presented.

MATERIALS AND METHODS: A total number of 155 patients (106 female and 49 male) (average age 57.48 ± 14.44 years) with 173 thyroid nodules (average size 24.89 ± 15.41 mm, range 5-68 mm) scheduled for fine-needle aspiration biopsy were recruited from March 2015 to May 2017. Comb-push shear elastography imaging was performed at longitudinal and transverse anatomic planes. Mean (Emean) and maximum (Emax) elasticity values were obtained.

RESULTS: Measurements at longitudinal view were statistically significantly higher than measurements at transverse view. Nodules with calcifications were associated with increased elasticity, and nodules with a vascular component or within an enlarged thyroid gland (goiter) were associated with a lower elasticity value. Receiver operating characteristic curve analysis was performed for Emean and Emax at each imaging plane and for the average of both planes. Sensitivity of 95.45%, specificity of 86.61%, 0.58 positive predictive value, and 0.99 negative predictive value were achieved by the average of the two planes for each Emean and Emax parameters, with area under the curve of 92% and 93%, and a cutoff value of 49.09 kPa and 105.61 kPa, respectively.

CONCLUSIONS: The elastic properties of thyroid nodules showed promise to be a good discriminator between malignant and benign nodules (P < .0001). However, probe orientation and internal features such as calcifications, vascular component, and goiter may influence the final elastography measurements. A larger number of malignant nodules need to be studied to further validate our results.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Gregory A, Bayat M, Kumar V, et al. Differentiation of Benign and Malignant Thyroid Nodules by Using Comb-push Ultrasound Shear Elastography: A Preliminary Two-plane View Study. Acad Radiol. 2018. PMID: 29573939. doi:10.1016/j.acra.2018.02.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。