基于体积的氟-18-氟脱氧葡萄糖PET/CT参数对甲状腺偶发瘤定性的诊断价值
本回顾性研究纳入5216例非甲状腺癌患者中99例甲状腺局灶性偶发瘤,评估PET/CT半定量参数及基于体积的功能参数MTV、TLG鉴别良恶性的价值。恶性偶发瘤的SUVmax、MTV、TLG均高于良性,TLG 4.0的AUC最高为0.895,与SUVmax无统计学差异。TLG 4.0阈值2.475时敏感度81.3%、特异度94.3%。
要点
- 甲状腺偶发瘤中恶性者SUVmax、MTV、TLG均显著高于良性。
- TLG 4.0鉴别良恶性的AUC最高(0.895),但与SUVmax无统计学差异。
- TLG 4.0阈值2.475时敏感度81.3%、特异度94.3%。
核心结论
- 基于体积的PET/CT参数与SUVmax联合可能对甲状腺偶发瘤的鉴别诊断具有临床价值。
研究设计与样本
- 回顾性研究,纳入5216例非甲状腺癌患者中99例甲状腺局灶性偶发瘤,均行PET/CT,评估半定量参数及基于体积的功能参数MTV、TLG,采用ROC曲线分析并以Hanley和McNeil检验比较AUC。
关键影像表现/征象
- 恶性甲状腺偶发瘤较良性更大(1.8 cm vs. 1.3 cm,p=0.006)。
- 恶性甲状腺偶发瘤SUVmax高于良性(11.3 vs. 4.8,p<0.001)。
- 恶性甲状腺偶发瘤MTV和TLG均高于良性(均p<0.001)。
诊断标准与关键数值
- 99例甲状腺偶发瘤中恶性64例(64.6%)、良性35例(35.4%)。
- TLG 4.0在所有半定量参数中鉴别良恶性表现最佳,AUC为0.895。
- TLG 4.0的AUC分别显著大于SUVmean、MTV 2.5、MTV 3.0、MTV 3.5、TLG 2.5和TLG 3.0的AUC(均p<0.05)。
- TLG 4.0与SUVmax的AUC之间无统计学差异(p>0.05)。
- TLG 4.0阈值2.475鉴别恶性甲状腺偶发瘤的敏感度81.3%、特异度94.3%。
临床应用与阅片要点
- 甲状腺局灶性偶发瘤可结合SUVmax与基于体积的MTV、TLG参数进行良恶性鉴别。
- TLG 4.0阈值2.475可作为鉴别恶性甲状腺偶发瘤的参考指标。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To assess clinical value of fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) for differentiation of malignant from benign focal thyroid incidentaloma.
MATERIALS AND METHODS: This retrospective study included 99 patients with focal thyroid incidentaloma of 5216 non-thyroid cancer patients that had undergone PET/CT. PET/CT semi-quantitative parameters, volume-based functional parameters, metabolic tumor volume (MTV), and total lesion glycolysis (TLG) of thyroid incidentaloma were assessed. Receiver-operating characteristic (ROC) analysis was conducted and areas under the curve (AUC) were compared by Hanley and McNeil test to evaluate usefulness of maximum standardized uptake value (SUVmax), MTV and TLG, as markers for differentiating malignant from benign thyroid incidentalomas.
RESULTS: Of 99 thyroid incidentalomas, 64 (64.6%) were malignant and 35 (35.4%) were benign. Malignant thyroid incidentalomas were larger (1.8 cm vs. 1.3 cm, p = 0.006), and had higher SUVmax (11.3 vs. 4.8, p < 0.001), MTV (all p < 0.001) and TLG (all p < 0.001) than benign. TLG 4.0 had the highest performance for differentiation of malignant from benign thyroid incidentaloma in all semi-quantitative parameters with AUC 0.895 by ROC curve analysis. AUC (TLG 4.0) was significantly larger than AUC (SUVmean), AUC (MTV 2.5), AUC (MTV 3.0), AUC (MTV 3.5), AUC (TLG 2.5), and AUC (TLG 3.0), respectively (all, p < 0.05). There was no statistical difference between AUC (TLG 4.0) and AUC (SUVmax) (p > 0.05). A threshold TLG 4.0 of 2.475 had 81.3% sensitivity and 94.3% specificity for identifying malignant thyroid incidentalomas.
CONCLUSION: Volume-based PET/CT parameters could potentially have clinical value in differential diagnosis of thyroid incidentaloma along with SUVmax.
引用
- Shi H, Yuan Z, Yuan Z, et al. Diagnostic Value of Volume-Based Fluorine-18-Fluorodeoxyglucose PET/CT Parameters for Characterizing Thyroid Incidentaloma. Korean J Radiol. 2018. PMID: 29520193. doi:10.3348/kjr.2018.19.2.342
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。