文献速递甲状腺与浅表技术与安全US

甲状腺结节剪切波弹性成像图像中的伪影

Artifacts in Shear Wave Elastography Images of Thyroid Nodules.
PubMed 文献 · Ultrasound Med Biol · 2018-03-21

本研究纳入178例患者共241个甲状腺结节,采用剪切波弹性成像获取1297幅图像并由1名有经验的医师回顾性判读。69.8%的图像存在某种伪影,18.6%的图像因伪影无法判读;最常见伪影为操作者误差(占全部图像44.6%),其中以压迫为主(36.5%)。

要点

  • 69.8%的剪切波弹性成像图像存在伪影,18.6%因伪影无法判读。
  • 操作者误差是最常见伪影类型(44.6%),其中压迫占36.5%。
  • 解剖因素(颈动脉搏动、邻近甲状腺或位于峡部)占11%,结节特征(囊性、钙化或大结节穿透不足)占17%。

核心结论

  • 甲状腺剪切波弹性成像图像中伪影常见,操作者误差是最常见类型,可通过充分认识和纠正加以改善。

研究设计与样本

  • 经机构伦理委员会批准、符合HIPAA的回顾性图像判读研究,纳入178例患者(40男、138女;平均年龄49岁,范围19-84岁)共241个甲状腺结节,行超声检查后于结节多个层面行横切和纵切剪切波弹性成像,共获取1297幅图像,平均每结节5.4±2.7幅,由1名有甲状腺弹性成像经验的判读医师回顾性判读。

关键影像表现/征象

  • 280幅图像(21.6%)评为质量良好,112幅(8.6%)评为中等质量且无伪影。
  • 905幅图像(69.8%)存在某种伪影,其中73.4%仍可判读。
  • 241幅图像(占全部图像18.6%)因伪影无法判读。
  • 操作者误差占全部图像44.6%,其中压迫占36.5%。
  • 解剖因素(颈动脉搏动、邻近甲状腺或位于峡部)占11%,结节特征(囊性、钙化或大结节穿透不足)占17%,其他无法解释的伪影占13%。

诊断标准与关键数值

  • 图像质量分为质量良好、中等质量无伪影、有伪影但仍可判读、因伪影无法判读。
  • 伪影类型分为操作者误差、解剖因素、结节特征及其他无法解释的原因。

临床应用与阅片要点

  • 判读甲状腺剪切波弹性成像图像时需识别操作者误差相关伪影,尤其是压迫所致伪影。
  • 位于峡部、邻近颈动脉或结节呈囊性、钙化、体积大时需注意相应伪影。
  • 作者认为通过充分认识和纠正伪影,操作者误差相关伪影容易纠正。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The purpose of the study described here was to evaluate the presence and types of artifacts seen in color elastograms in thyroid elastography using shear wave elastography. This Health Insurance Portability and Accountability Act of 1996 (HIPAA)-compliant study was approved by the ethics committee of our institution, and all patients provided written informed consent. One hundred seventy-eight patients (40 men and 138 women; mean age, 49 y; range, 19-84 y) were enrolled for a total of 241 thyroid nodules. After a short ultrasound (US) examination, SWE images were acquired at multiple levels in the nodule in transverse and longitudinal orientations. A total of 1297 images were obtained from 241 nodules for an average of 5.4 ± 2.7 (mean ± standard deviation) images per nodule. A retrospective review of all images was performed by one reviewer experienced in thyroid elastography. Two hundred eighty images (21.6%) were rated as good quality, and 112 (8.6%) were rated as moderate quality without artifacts. A total of 905 (69.8%) images had some artifact present, though most of these images (73.4%) were still interpretable. Two hundred forty-one images (18.6% of all images) were considered uninterpretable because of artifact. The most common types of artifacts were due to operator error (44.6% of all images), primarily compression (36.5% of all images). Other artifacts seen were due to anatomy (presence of carotid pulsation or adjacent to thyroid or location in isthmus, 11% of all images), nodule characteristics (cystic and calcified nodules or large nodules with lack of penetration, 17% of all images) and other artifacts that could not be explained by the prior mentioned causes (13% of all images). Our study indicates that artifacts are common in elastography images. Operator error was the most common type of artifact we saw. This should be easily correctable by adequate knowledge and recognition with subsequent correction of the artifacts.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Dighe M, Hippe DS, Thiel J, et al. Artifacts in Shear Wave Elastography Images of Thyroid Nodules. Ultrasound Med Biol. 2018. PMID: 29573887. doi:10.1016/j.ultrasmedbio.2018.02.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。