手持超声测量声速评估乳腺密度:一种评估乳腺癌风险并定制筛查方案的新型生物标志物
在106名女性中由两名放射技师用常规超声系统测量乳腺三个节段的声速,并与乳腺X线ACR密度分类比较。声速超声检查耗时不足2分钟,声速与ACR密度分级显著相关(rs=0.746),诊断致密乳腺(ACR c和d)的敏感度86.2%、特异度85.2%、AUC 0.887。
要点
- 声速超声测量乳腺密度与乳腺X线ACR分级显著相关,全乳腺分类相关系数rs=0.746。
- 诊断致密乳腺(ACR c和d)的敏感度86.2%、特异度85.2%、AUC 0.887。
- 声速超声检查耗时不足2分钟,受检者舒适度评分和读者间一致性均优于乳腺X线。
核心结论
- 手持声速超声可由放射技师无不适、无辐射地测量乳腺密度,读者间一致性高,且与乳腺X线ACR乳腺密度分类显著相关。
研究设计与样本
- 在106名女性中,由两名放射技师用常规超声系统测量乳腺后乳晕区、内侧段和外侧段的声速,并与ACR乳腺X线密度分类(a=脂肪型至d=极度致密型)比较;四名盲法读者评估平均声速、Δ声速和ACR-MG密度。
诊断标准与关键数值
- 密度a-d的平均声速分别为1421 m/s(SD 14)、1432 m/s(SD 17)、1448 m/s(SD 20)和1500 m/s(SD 31),各组间差异显著(p<0.001)。
- 声速与ACR-MG乳腺密度的节段相关性rs=0.622(p<0.001),全乳腺分类相关性升高至rs=0.746(p<0.001)。
- 声速超声诊断致密乳腺(ACR c和d)的敏感度86.2%、特异度85.2%、AUC 0.887。
临床应用与阅片要点
- 声速超声可在常规超声系统上实现,检查耗时不足2分钟,测量乳腺密度无需辐射。
- 声速超声的受检者舒适度评分和读者间一致性均显著优于乳腺X线(舒适度1.05 vs 2.05,读者间一致性0.982 vs 0.774)。
- 作者指出声速超声显示出对乳腺密度进行可量化、成本效益评估的潜力。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess feasibility and diagnostic accuracy of a novel hand-held ultrasound (US) method for breast density assessment that measures the speed of sound (SoS), in comparison to the ACR mammographic (MG) categories.
METHODS: ACR-MG density (a=fatty to d=extremely dense) and SoS-US were assessed in the retromamillary, inner and outer segments of 106 women by two radiographers. A conventional US system was used for SoS-US. A reflector served as timing reference for US signals transmitted through the breasts. Four blinded readers assessed average SoS (m/s), ΔSoS (segment-variation SoS; m/s) and the ACR-MG density. The highest SoS and ΔSoS values of the three segments were used for MG-ACR whole breast comparison.
RESULTS: SoS-US breasts were examined in <2 min. Mean SoS values of densities a-d were 1,421 m/s (SD 14), 1,432 m/s (SD 17), 1,448 m/s (SD 20) and 1,500 m/s (SD 31), with significant differences between all groups (p<0.001). The SoS-US comfort scores and inter-reader agreement were significantly better than those for MG (1.05 vs. 2.05 and 0.982 vs. 0.774; respectively). A strong segment correlation between SoS and ACR-MG breast density was evident (rs=0.622, p=<0.001) and increased for full breast classification (rs=0.746, p=<0.001). SoS-US allowed diagnosis of dense breasts (ACR c and d) with sensitivity 86.2 %, specificity 85.2 % and AUC 0.887.
CONCLUSIONS: Using hand-held SoS-US, radiographers measured breast density without discomfort, readers evaluated measurements with high inter-reader agreement, and SoS-US correlated significantly with ACR-MG breast-density categories.
KEY POINTS: • The novel speed-of-sound ultrasound correlated significantly with mammographic ACR breast density categories. • Radiographers measured breast density without women discomfort or radiation. • SoS-US can be implemented on a standard US machine. • SoS-US shows potential for a quantifiable, cost-effective assessment of breast density.
引用
- Sanabria SJ, Goksel O, Martini K, et al. Breast-density assessment with hand-held ultrasound: A novel biomarker to assess breast cancer risk and to tailor screening? Eur Radiol. 2018. PMID: 29556766. doi:10.1007/s00330-017-5287-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。