文献速递乳腺US

Meta分析:超声造影与常规超声鉴别乳腺良恶性病变的比较

Meta-Analysis: Contrast-Enhanced Ultrasound Versus Conventional Ultrasound for Differentiation of Benign and Malignant Breast Lesions.
PubMed 文献 · Ultrasound Med Biol · 2018-03-09

该Meta分析纳入10项以病理为金标准的研究,比较超声造影(CEUS)、常规超声联合超声造影(US+CEUS)与常规超声(US)鉴别乳腺病变的诊断效能。CEUS与US比较的汇总敏感度为0.93 vs 0.87、特异度为0.86 vs 0.72;US+CEUS与US比较的汇总敏感度为0.94 vs 0.87、特异度为0.86 vs 0.80。CEUS和US+CEUS诊断乳腺恶性肿瘤的SROC曲线下面积均统计学高于US(p=0.003和p=0.000),US+CEUS的阴性似然比低。

要点

  • CEUS鉴别乳腺病变的汇总敏感度0.93、特异度0.86,均高于常规US的0.87和0.72。
  • US+CEUS的汇总敏感度0.94、特异度0.86,高于常规US的0.87和0.80。
  • CEUS和US+CEUS诊断乳腺恶性肿瘤的SROC曲线下面积均统计学高于US。

核心结论

  • CEUS单独及US+CEUS鉴别乳腺病变的诊断效能均优于常规US,且US+CEUS的阴性似然比低。

研究设计与样本

  • Meta分析,共纳入10项研究,其中9项比较CEUS与US,5项比较US+CEUS与US,均以病理结果为金标准。

诊断标准与关键数值

  • CEUS vs US:汇总敏感度0.93(95%CI 0.91-0.95)vs 0.87(95%CI 0.85-0.90),汇总特异度0.86(95%CI 0.84-0.88)vs 0.72(95%CI 0.69-0.75)。
  • US+CEUS vs US:汇总敏感度0.94(95%CI 0.92-0.96)vs 0.87(95%CI 0.84-0.90),汇总特异度0.86(95%CI 0.82-0.89)vs 0.80(95%CI 0.76-0.84)。
  • 诊断乳腺恶性肿瘤的SROC曲线下面积:CEUS高于US(p=0.003),US+CEUS高于US(p=0.000)。
  • US+CEUS的阴性似然比低。

临床应用与阅片要点

  • 在鉴别乳腺良恶性病变时,可参考CEUS或US+CEUS较常规US具有更高的汇总敏感度和特异度。
  • US+CEUS的阴性似然比低,可作为原文结论中提及的诊断效能优势之一。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

This meta-analysis aimed to compare the diagnostic performance of contrast-enhanced ultrasound (CEUS), conventional ultrasound (US) combined with CEUS (US + CEUS) and US for distinguishing breast lesions. From thorough literature research, studies that compared the diagnostic performance of CEUS versus US or US + CEUS versus US, using pathology results as the gold standard, were included. A total of 10 studies were included, of which 9 compared the diagnostic performance of CEUS and US, and 5 studies compared US + CEUS and US. In those comparing CEUS versus US, the pooled sensitivity was 0.93 (95% CI: 0.91-0.95) versus 0.87 (95% CI: 0.85-0.90) and pooled specificity was 0.86 (95% CI: 0.84-0.88) versus 0.72 (95% CI: 0.69-0.75). In studies comparing US + CEUS versus US, the pooled sensitivity was 0.94 (95% CI: 0.92-0.96) versus 0.87 (95% CI: 0.84-0.90) and pooled specificity was 0.86 (95% CI: 0.82-0.89) versus 0.80 (95% CI: 0.76-0.84). In terms of diagnosing breast malignancy, areas under the curve of the summary receiver operating characteristic (of both CEUS (p = 0.003) and US + CEUS (p = 0.000) were statistically higher than that of US. Both CEUS alone and US + CEUS had better diagnostic performance than US in differentiation of breast lesions, and US + CEUS also had low negative likelihood ratio.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Li Q, Hu M, Chen Z, et al. Meta-Analysis: Contrast-Enhanced Ultrasound Versus Conventional Ultrasound for Differentiation of Benign and Malignant Breast Lesions. Ultrasound Med Biol. 2018. PMID: 29530434. doi:10.1016/j.ultrasmedbio.2018.01.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。