文献速递乳腺US

乳腺病灶弹性参数与胶原纤维特征的相关性研究

Correlation between elastic parameters and collagen fibre features in breast lesions.
PubMed 文献 · Clin Radiol · 2018-03-03

研究采用剪切波弹性成像测量54例乳腺病灶手术前的平均弹性(Emean)和最大弹性(Emax),并将病灶切片行苦味酸-天狼星红染色显示细胞外基质胶原纤维,按形态和排列分为0~3类;双变量相关分析显示Emean与分类的相关系数为0.693(p < 0.001),Emax与分类的相关系数为0.794(p < 0.001);36个恶性病灶中Emean与分类的相关系数为0.658(p < 0.001),Emax与分类的相关系数为0.771(p < 0.001);结论认为剪切波弹性成像测得的Emean和Emax与细胞外基质胶原纤维形态和排列分类呈正相关。

要点

  • 剪切波弹性成像测得的Emean与胶原纤维分类相关系数0.693(p < 0.001),Emax为0.794(p < 0.001)。
  • 36个恶性病灶中Emean与分类相关系数0.658(p < 0.001),Emax为0.771(p < 0.001)。
  • 细胞外基质胶原纤维形态和排列改变可能解释乳腺病灶硬度的变化。

核心结论

  • 剪切波弹性成像测得的乳腺病灶Emean和Emax与细胞外基质胶原纤维形态和排列分类呈正相关;细胞外基质胶原纤维形态和排列改变可能解释乳腺病灶硬度的变化。

研究设计与样本

  • 研究纳入54例患者,手术切除前采用剪切波弹性成像测量乳腺病灶硬度,以Emean和Emax表示;病灶切片行苦味酸-天狼星红染色显示细胞外基质胶原纤维,按形态和排列特征分为0~3类;采用双变量相关分析分析弹性参数与胶原纤维分类的关系。

诊断标准与关键数值

  • 胶原纤维分类标准:0类为类似正常乳腺组织的波浪状胶原纤维;1类为肿瘤巢周围绷紧的平行胶原纤维;2类为变直且排列整齐、倾向于垂直于肿瘤边界的胶原纤维;3类为蜂窝状排列的胶原纤维。全部54个病灶中Emean与分类相关系数0.693(p < 0.001),Emax与分类相关系数0.794(p < 0.001);36个恶性病灶中Emean与分类相关系数0.658(p < 0.001),Emax与分类相关系数0.771(p < 0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To correlate elastic parameters with collagen fibre shape and arrangement features in breast lesions.

MATERIALS AND METHODS: Shear-wave elastography (SWE) was used to measure the stiffness of breast lesions in 54 patients before surgical removal. The value of stiffness was expressed as the mean and maximum elasticity (Emean and Emax). Lesions were sliced and stained with picric acid-sirius red to display the extracellular matrix (ECM) collagen fibre. The categories of the collagen fibres were based on the shape and arrangement features, i.e., category 0, wavy collagen fibres similar to normal breast tissue; category 1, taut parallel collagen fibres around tumour nests; category 2, straightened and aligned collagen fibres tending to be perpendicular to the tumour boundary; category 3, collagen fibre in a honeycomb arrangement. Bivariate correlation analysis was used to analyse the relationship between elastic parameters and collagen fibre category.

RESULTS: For all 54 lesions, the correlation coefficient between Emean and category was 0.693 (p < 0.001), and between Emax and category was 0.794 (p < 0.001). For 36 malignant lesions, the correlation coefficient between Emean and category was 0.658 (p < 0.001), and between Emax and category was 0.771 (p < 0.001).

CONCLUSION: Emean and Emax of breast lesions evaluated by SWE were positively correlated with ECM collagen fibre shape and arrangement category. Changes of ECM collagen fibre shape and arrangement may account for the stiffness variations of breast lesions.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Shi XQ, Li J, Qian L, et al. Correlation between elastic parameters and collagen fibre features in breast lesions. Clin Radiol. 2018. PMID: 29510833. doi:10.1016/j.crad.2018.01.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。