乳腺X线摄影影像组学特征预测乳腺癌分子亚型
该回顾性研究纳入2015年331例中国女性浸润性乳腺癌患者,从数字乳腺X线图像提取39个影像组学特征,采用朴素贝叶斯分类器区分三阴性、HER2富集型及luminal型亚型。联合头尾位与内外斜位图像时分类性能最佳,三阴性vs非三阴性AUC为0.865、准确率0.796。
要点
- 联合头尾位与内外斜位图像时亚型分类性能优于单一体位。
- 三阴性vs非三阴性AUC 0.865、准确率0.796,为三类任务中最高。
- 圆形度、凹陷度、灰度均值、相关性4个特征在亚型分类中差异有统计学意义(P<.05)。
核心结论
- 从数字乳腺X线图像提取的乳腺肿瘤定量影像组学特征与乳腺癌分子亚型相关。
- 未来需更大规模研究进一步评估上述发现。
研究设计与样本
- 经机构审查委员会批准的回顾性研究,纳入2015年诊断为浸润性乳腺癌的331例中国女性。
- 病灶包括三阴性29例、HER2富集型45例、luminal A型36例、luminal B型221例。
- 从分割病灶区域提取39个定量影像组学特征,包括形态学、灰度统计和纹理特征。
- 采用朴素贝叶斯机器学习方案分类,并用最小绝对收缩和选择算子法筛选最具预测性的特征。
- 分类性能以受试者工作特征曲线下面积和准确率评估。
诊断标准与关键数值
- 三阴性vs非三阴性:联合头尾位与内外斜位图像时AUC 0.865、准确率0.796。
- HER2富集型vs非HER2富集型:联合头尾位与内外斜位图像时AUC 0.784、准确率0.748。
- luminal(A+B)vs非luminal:联合头尾位与内外斜位图像时AUC 0.752、准确率0.788。
- 最小绝对收缩和选择算子法选出12个最具预测性特征,其中圆形度、凹陷度、灰度均值和相关性4个特征在亚型分类中差异有统计学意义(P<.05)。
局限性
- 原文结论指出未来需更大规模研究进一步评估这些发现。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: This study aimed to investigate whether quantitative radiomic features extracted from digital mammogram images are associated with molecular subtypes of breast cancer.
MATERIALS AND METHODS: In this institutional review board-approved retrospective study, we collected 331 Chinese women who were diagnosed with invasive breast cancer in 2015. This cohort included 29 triple-negative, 45 human epidermal growth factor receptor 2 (HER2)-enriched, 36 luminal A, and 221 luminal B lesions. A set of 39 quantitative radiomic features, including morphologic, grayscale statistic, and texture features, were extracted from the segmented lesion area. Three binary classifications of the subtypes were performed: triple-negative vs non-triple-negative, HER2-enriched vs non-HER2-enriched, and luminal (A + B) vs nonluminal. The Naive Bayes machine learning scheme was employed for the classification, and the least absolute shrink age and selection operator method was used to select the most predictive features for the classifiers. Classification performance was evaluated by the area under receiver operating characteristic curve and accuracy.
RESULTS: The model that used the combination of both the craniocaudal and the mediolateral oblique view images achieved the overall best performance than using either of the two views alone, yielding an area under receiver operating characteristic curve (or accuracy) of 0.865 (0.796) for triple-negative vs non-triple-negative, 0.784 (0.748) for HER2-enriched vs non-HER2-enriched, and 0.752 (0.788) for luminal vs nonluminal subtypes. Twelve most predictive features were selected by the least absolute shrink age and selection operator method and four of them (ie, roundness, concavity, gray mean, and correlation) showed a statistical significance (P< .05) in the subtype classification.
CONCLUSIONS: Our study showed that quantitative radiomic imaging features of breast tumor extracted from digital mammograms are associated with breast cancer subtypes. Future larger studies are needed to further evaluate the findings.
引用
- Ma W, Zhao Y, Ji Y, et al. Breast Cancer Molecular Subtype Prediction by Mammographic Radiomic Features. Acad Radiol. 2018. PMID: 29526548. doi:10.1016/j.acra.2018.01.023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。