文献速递腹部泌尿生殖MR

基于U-net的金字塔Lucas-Kanade配准在自由呼吸多b值肾脏扩散MRI中的性能

Performance of U-net based pyramidal lucas-kanade registration on free-breathing multi-b-value diffusion MRI of the kidney.
PubMed 文献 · Br J Radiol · 2018-03-28

研究纳入10名健康受试者,提出将U-net肾脏分割与金字塔Lucas-Kanade配准结合的全自动框架,用于自由呼吸多b值肾脏扩散MRI。配准后皮质(p<0.05)和髓质(p<0.01)的NRMSE显著降低,专家视觉评分显示配准后图像肾脏对位显著改善。结论认为该框架可有效减少错位多b值DWI的运动伪影及ADC、f、D、D*估计的不准确性。

要点

  • 配准后皮质NRMSE显著降低(p<0.05),髓质NRMSE显著降低(p<0.01)。
  • 专家视觉评分显示配准后ADC、f、D、D*图的肾脏对位显著改善。
  • U-net分割限定肾脏解算范围,提高金字塔Lucas-Kanade配准精度。

核心结论

  • 所提出的全自动框架可有效减少错位多b值DWI的运动伪影,并降低ADC、f、D和D*估计的不准确性。

研究设计与样本

  • 研究纳入10名健康受试者参与实验,采用U-net获取肾脏轮廓进行分割,分割后的肾脏作为金字塔Lucas-Kanade配准方法的感兴趣区;在皮质和髓质选取8个感兴趣区,通过比较双指数IVIM模型拟合数据配准前后的NRMSE值评估数据稳定性。

诊断标准与关键数值

  • 配准后皮质NRMSE显著低于配准前(p<0.05)。
  • 配准后髓质NRMSE显著低于配准前(p<0.01)。
  • 专家视觉评分显示配准后图像中肾脏对位有显著改善。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: In free-breathing multi-b-value diffusion-weighted imaging (DWI), a series of images typically requires several minutes to collect. During respiration the kidney is routinely displaced and may also undergo deformation. These respiratory motion effects generate artifacts and these are the main sources of error in the quantification of intravoxel incoherent motion (IVIM) derived parameters. This work proposes a fully automated framework that combines a kidney segmentation to improve the registration accuracy.

METHODS: 10 healthy subjects were recruited to participate in this experiment. For the segmentation, U-net was adopted to acquire the kidney's contour. The segmented kidney then served as a region of interest (ROI) for the registration method, known as pyramidal Lucas-Kanade. Our proposed framework confines the kidney's solution range, thus increasing the pyramidal Lucas-Kanade's accuracy. To demonstrate the feasibility of our presented framework, eight regions of interest were selected in the cortex and medulla, and data stability was estimated by comparing the normalized root-mean-square error (NRMSE) values of the fitted data from the bi-exponential intravoxel incoherent motion model pre- and post- registration.

RESULTS: The results show that the NRMSE was significantly lower after registration both in the cortex (p < 0.05) and medulla (p < 0.01) during free-breathing measurements. In addition, expert visual scoring of the derived apparent diffusion coefficient (ADC), f, D and D* maps indicated there were significant improvements in the alignment of the kidney in the post-registered image.

CONCLUSION: The proposed framework can effectively reduce the motion artifacts of misaligned multi-b-value DWIs and the inaccuracies of the ADC, f, D and D* estimations. Advances in knowledge: This study demonstrates the feasibility of our proposed fully automated framework combining U-net based segmentation and pyramidal Lucas-Kanade registration method for improving the alignment of multi-b-value diffusion-weighted MRIs and reducing the inaccuracy of parameter estimation during free-breathing.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Lv J, Huang W, Zhang J, et al. Performance of U-net based pyramidal lucas-kanade registration on free-breathing multi-b-value diffusion MRI of the kidney. Br J Radiol. 2018. PMID: 29528241. doi:10.1259/bjr.20170813

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。