双参数与多参数MRI对临床显著性前列腺癌的诊断准确性:不同经验阅片者间的比较
回顾性纳入85例因PSA升高和/或直肠指检怀疑前列腺癌行1.5T前列腺MRI的患者,比较双参数(T2WI+DWI)与多参数(加DCE)方案,由3名经验不同(7、3、1年)的放射科医生按PI-RADS v2独立评分。三种阅片者在两方案间对临床显著性肿瘤的检出无显著差异;双参数与多参数方案AUC分别为阅片者1 0.68-0.72、阅片者2 0.72-0.70、阅片者3 0.60-0.54。结论认为双参数方案诊断准确性与标准多参数方案相当,阅片者经验未显著改变两种方案的诊断性能。
要点
- 双参数(T2WI+DWI)与多参数(加DCE)MRI对临床显著性前列腺癌的诊断准确性相当。
- 阅片者经验(7、3、1年)未显著改变双参数或多参数方案的诊断性能。
- 各阅片者两方案间对临床显著性肿瘤的检出无显著差异。
核心结论
- 双参数MRI方案(T2WI+DWI)对临床显著性前列腺癌的诊断准确性与标准多参数方案(加DCE)相当,且阅片者经验未显著改变两种方案的诊断性能。
研究设计与样本
- 回顾性研究,85例因PSA升高和/或直肠指检怀疑前列腺癌的患者行1.5T前列腺MRI,由3名分别有7年、3年、1年前列腺MR阅片经验的放射科医生按PI-RADS v2独立评分两套图像(Set 1双参数,Set 2多参数)。
诊断标准与关键数值
- 按PI-RADS v2评分并二分法计算诊断性能;双参数与多参数方案的AUC分别为阅片者1 0.68-0.72、阅片者2 0.72-0.70、阅片者3 0.60-0.54。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: MRI plays a crucial role to identify men with a high likelihood of clinically significant prostate cancer who require immediate biopsy. The added value of DCE MRI in combination with T2-weighted imaging and DWI is controversial (risks related to gadolinium administration, duration of MR exam, financial burden, effects on diagnostic performance). A comparison of a biparametric and a standard multiparametric MR imaging protocol, taking into account the different experience of the readers, may help to choose the best MR approach regarding diagnostic performance.
PURPOSE: To determine the added value of dynamic contrasted-enhanced imaging (DCE) over T2-weighted imaging (T2-WI) and diffusion weighted imaging (DWI) for the detection of clinically significant prostate cancer, and to evaluate how it affects the diagnostic performance of three readers with different grade of experience in prostate imaging.
MATERIALS AND METHODS: Eighty-five patients underwent prostate MR examination at 1.5 T MR scanner performed because of elevated prostate-specific antigen level and/or suspicion of prostate cancer at digital rectal examination. Two MR images sets (Set 1 = biparametric, Set 2 = multiparametric) were retrospectively and independently scored by three radiologists with 7, 3 and 1 years of experience in prostate MR imaging respectively, according to PI-RADS v2. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated by dichotomizing reader scores. Receiver operating characteristic (ROC) analysis was performed and areas under the curve (AUCs) were calculated for each reader and image set. A comparison of ROC curves was performed to test the difference between the areas under the ROC curves among the three readers.
RESULTS: There was no significant difference regarding the detection of clinically significant tumor among the three readers between the two image sets. The AUC for the bi-parametric and multi-parametric MR imaging protocol was respectively 0.68-0.72 (Reader 1), 0.72-0.70 (Reader 2) and 0.60-0.54 (Reader 3). ROC curve comparison revealed no statistically significant differences for each protocol among the most experienced (Reader 1) and the other readers (Readers 2-3).
CONCLUSION: The diagnostic accuracy of a bi-parametric MR imaging protocol consisting of T2-weighted imaging and DWI is comparable with that of a standard multi-parametric imaging protocol for the detection of clinically significant prostate cancer. The experience of the reader does not significantly modify the diagnostic performance of both MR protocols.
引用
- Di Campli E, Delli Pizzi A, Seccia B, et al. Diagnostic accuracy of biparametric vs multiparametric MRI in clinically significant prostate cancer: Comparison between readers with different experience. Eur J Radiol. 2018. PMID: 29571792. doi:10.1016/j.ejrad.2018.01.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。