文献速递外周血管介入腹部DSA

经颈静脉肝内门体分流术(TIPS)功能障碍:分流修订术后采用二维灌注血管造影定量评估血流与灌注变化

Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction: quantitative assessment of flow and perfusion changes using 2D-perfusion angiography following shunt revision.
PubMed 文献 · Abdom Radiol (NY) · 2018-01-01

本研究纳入15例连续接受TIPS修订术的患者,利用二维灌注血管造影(2D-PA)对修订前后的DSA序列进行后处理,定量分析血流与灌注变化。结果显示修订术后门体压力梯度显著降低,TIPS管腔及右心房的峰值密度比和曲线下面积比显著升高,肝实质峰值密度比显著降低,且压力梯度变化与右心房灌注参数变化显著相关;2D-PA参数的可重复性ICC为0.88-0.99。作者认为2D-PA是定量评估TIPS修订术中血流与灌注变化的可行方法,可能成为单纯压力测量的有价值补充。

要点

  • TIPS修订术后门体压力梯度由17.1±6.3 mmHg降至8.9±4.3 mmHg(p<0.0001)。
  • 修订术后PDTIPS/PDinflow由0.22升至0.35(p=0.0014),AUCTIPS/AUCinflow由0.24升至0.39(p=0.0012)。
  • 压力梯度变化与PDatrium/PDinflow升高(r=-0.77,p=0.0012)及AUCatrium/AUCinflow升高(r=-0.76,p=0.0018)显著相关。

核心结论

  • 2D-PA是定量评估TIPS修订术中血流与灌注变化的可行方法,可能成为单纯压力测量的有价值补充。

研究设计与样本

  • 研究纳入15例连续接受TIPS修订术的患者(54±14岁,男7例、女8例),对修订过程中采集的DSA序列用专用软件进行后处理。

关键影像表现/征象

  • 在主门静脉设置参考感兴趣区(输入函数),在TIPS管腔、肝实质和右心房设置目标感兴趣区,于修订前后对应区域放置。
  • 2D-PA评估包括达峰时间(TTP)、峰值密度(PD)和曲线下面积(AUC)。
  • 计算修订前后参考感兴趣区与目标感兴趣区的比值:TTPparenchyma/TTPinflow、PDparenchyma/PDinflow、AUCparenchyma/AUCinflow、TTPTIPS/TTPinflow、PDTIPS/PDinflow、AUCTIPS/AUCinflow、TTPatrium/TTPinflow、PDatrium/PDinflow、AUCatrium/AUCinflow。

诊断标准与关键数值

  • TIPS修订术后门体压力梯度由17.1±6.3 mmHg降至8.9±4.3 mmHg(p<0.0001)。
  • PDTIPS/PDinflow由0.22升至0.35(p=0.0014),AUCTIPS/AUCinflow由0.24升至0.39(p=0.0012)。
  • PDatrium/PDinflow由0.32升至0.78(p=0.0004),AUCatrium/AUCinflow由0.3升至0.79(p<0.0001)。
  • PDparenchyma/PDinflow由0.14降至0.1(p=0.0084)。
  • 压力梯度变化与PDatrium/PDinflow升高(r=-0.77,p=0.0012)及AUCatrium/AUCinflow升高(r=-0.76,p=0.0018)显著相关;2D-PA参数的ICC为0.88-0.99。

临床应用与阅片要点

  • 作者认为2D-PA可能成为单纯压力测量的有价值补充。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To analyze the feasibility of 2D-perfusion angiography (2D-PA) to quantify flow and perfusion changes pre- and post-transjugular intrahepatic portosystemic shunt (TIPS) revision.

MATERIALS AND METHODS: Fifteen consecutive patients (54 ± 14 years, seven men and eight women) scheduled for TIPS revision were included in this study. To quantify flow and perfusion changes caused by TIPS revision, digital subtraction angiography (DSA) series acquired during the revision were post-processed using a dedicated software. Reference region-of-interest (ROI) in the main portal vein (input function) and target ROIs in the TIPS lumen, the liver parenchyma and in the right atrium were placed in corresponding areas on DSA pre- and post-TIPS revision. 2D-PA evaluation included time to peak (TTP), peak density (PD), and the area under the curve (AUC) assessment. The ratios of reference ROI to target ROIs pre- and post-TIPS revision were calculated (TTPparenchyma/TTPinflow, PDparenchyma/PDinflow, AUCparenchyma/AUCinflow, TTPTIPS/TTPinflow, PDTIPS/PDinflow, AUCTIPS/AUCinflow, TTPatrium/TTPinflow, PDatrium/PDinflow, and AUCatrium/AUCinflow). Pressure measurements pre- and post-TIPS revision were performed and correlated to the 2D-PA parameters. Reproducibility of 2D-PA was assessed by the intra-class correlation coefficient (ICC).

RESULTS: The portosystemic pressure gradient was significantly reduced following TIPS revision (17.1 ± 6.3 vs. 8.9 ± 4.3 mmHg; p < 0.0001). PDTIPS/PDinflow (0.22 vs. 0.35; p = 0.0014) and AUCTIPS/AUCinflow (0.24 vs. 0.39; p = 0.0012) increased significantly. Likewise, PDatrium/PDinflow (0.32 vs. 0.78; p = 0.0004) and AUCatrium/AUCinflow (0.3 vs. 0.79; p < 0.0001) increased, whereas PDparenchyma/PDinflow decreased significantly (0.14 vs. 0.1; p = 0.0084). Pressure gradient changes correlated significantly with the increase in PDatrium/PDinflow (r = - 0.77, p = 0.0012) and AUCatrium/AUCinflow (r = - 0.76, p = 0.0018). ICC of the 2D-PA parameters was in the range of 0.88-0.99.

CONCLUSION: 2D-PA offers a feasible approach to quantify flow and perfusion changes during TIPS revision. Therefore, 2D-PA may be a valuable amendment to mere pressure measurements.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Maschke SK, Werncke T, Renne J, et al. Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction: quantitative assessment of flow and perfusion changes using 2D-perfusion angiography following shunt revision. Abdom Radiol (NY). 2018. PMID: 29500653. doi:10.1007/s00261-018-1547-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。