腹部快速kVp切换双能CT虚拟单能成像对CT纹理分析的影响

Virtual monoenergetic imaging in rapid kVp-switching dual-energy CT (DECT) of the abdomen: impact on CT texture analysis.
PubMed 文献 · Abdom Radiol (NY) · 2018-01-01

本研究纳入30例连续患者,在快速kVp切换双能CT上行门静脉期腹部扫描,重建40/50/60/70/80 keV五个能级的5 mm轴位虚拟单能图像并对肝脏行CT纹理分析。结果显示,偏度和峰度在各能级及各空间尺度滤波器下均无显著变化;平均强度在滤波器2–6下无变化,但SSF=0时平均衰减随keV升高而显著降低(p<0.001);熵、正像素均值(MPP)和标准差(SD)在所有6个滤波器下均随keV升高而显著降低(p<0.001)。

要点

  • 偏度和峰度在各能级及各空间尺度滤波器下均无显著变化(p>0.05)。
  • SSF=0时平均衰减随keV升高而显著降低(p<0.001),80 keV为91.2±2.9 HU、40 keV为250.5±10.1 HU。
  • 熵、MPP和SD在所有6个滤波器下均随keV升高而显著降低(p<0.001),报告纹理参数时需注明keV。

核心结论

  • 单能图像的能级对不同CT纹理分析参数影响不一:偏度、峰度及滤波后平均强度无显著变化,而平均衰减、熵、MPP和SD随能级升高显著降低(p<0.001)。

研究设计与样本

  • 纳入30例连续患者(59.3±12岁,范围34–77岁,17男:13女),在快速kVp切换双能CT扫描仪上行门静脉期腹部CT,重建40/50/60/70/80 keV五个能级的5 mm轴位单能图像并对肝脏行CT纹理分析,采用重复测量方差分析比较各参数。

诊断标准与关键数值

  • CT纹理分析采用滤波-直方图技术,空间尺度滤波器(SSF)值为0–6,各SSF值下量化平均强度、标准差(SD)、熵、正像素均值(MPP)、偏度和峰度;SSF=0时平均衰减在80、70、60、50、40 keV分别为91.2±2.9、108.7±3.6、136.1±4.7、179.8±6.9、250.5±10.1 HU,随keV升高显著降低(p<0.001);偏度和峰度在所有6个滤波器下均无变化(p>0.05);平均强度在滤波器2–6下无变化(p>0.05);熵、MPP和SD在所有6个滤波器下随keV升高显著降低(p<0.001)。

临床应用与阅片要点

  • 阅片及报告纹理分析结果时,应记录并注明所用虚拟单能图像的keV能级;偏度和峰度在不同能级间表现稳定,而熵、MPP、SD及SSF=0的平均衰减随keV变化明显。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To study the impact of keV levels of virtual monoenergetic images generated from rapid kVp-switching dual-energy CT (rsDECT) on CT texture analysis (CTTA).

METHODS: This study included 30 consecutive patients (59.3 ± 12 years; range 34-77 years; 17M:13F) who underwent portal venous phase abdominal CT on a rsDECT scanner. Axial 5-mm monoenergetic images at 5 energy levels (40/50/60/70/80 keV) were created and CTTA of liver was performed. CTTA comprised a filtration-histogram technique with different spatial scale filter (SSF) values (0-6). CTTA quantification at each SSF value included histogram-based statistical parameters such as mean intensity, standard deviation (SD), entropy, mean of positive pixels (MPP), skewness, and kurtosis. The values were compared using repeated measures ANOVA.

RESULTS: Among the different CTTA metrics, mean intensity (at SSF > 0), skewness, and kurtosis did not show variability whereas entropy, MPP, and SD varied with different keV levels. There was no change in skewness and kurtosis values for all 6 filters (p > 0.05). Mean intensity showed no change for filters 2-6 (p > 0.05). Mean intensity at SSF = 0 i.e., mean attenuations were 91.2 ± 2.9, 108.7 ± 3.6, 136.1 ± 4.7, 179.8 ± 6.9, and 250.5 ± 10.1 HU for 80, 70, 60, 50, and 40 keV images, respectively demonstrating significant variability (decrease) with increasing keV levels (p < 0.001). Entropy, MPP, and SD values showed a statistically significant decrease with increasing keV of monoenergetic images on all 6 filters (p < 0.001).

CONCLUSION: The energy levels of monoenergetic images have variable impact on the different CTTA parameters, with no significant change in skewness, kurtosis, and filtered mean intensity whereas significant decrease in mean attenuation, entropy, MPP, and SD values with increasing energy levels.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。