文献速递介入腹部外周血管CTDSA

球囊阻塞逆行经静脉闭塞术治疗胃静脉曲张:术中锥形束CT的作用

Plug-Assisted Retrograde Transvenous Obliteration for the Treatment of Gastric Varices: The Role of Intra-Procedural Cone-Beam Computed Tomography.
PubMed 文献 · Korean J Radiol · 2018-02-22

回顾性分析17例胃静脉曲张患者接受球囊阻塞逆行经静脉闭塞术(PARTO)的技术与临床结局,术中非增强锥形束CT(CBCT)显示15例完全栓塞、2例不完全栓塞,后者追加明胶海绵后达完全栓塞;随访CT示全部17例胃静脉曲张及门体分流明显缩小或完全闭塞,随访期间无曲张静脉出血。

要点

  • 术中CBCT可即时、准确评估PARTO对胃静脉曲张的栓塞是否完全。
  • CBCT发现不完全栓塞时,追加明胶海绵注射后可达完全栓塞。
  • 随访CT示全部17例胃静脉曲张及门体分流明显缩小或完全闭塞。

核心结论

  • PARTO治疗胃静脉曲张在技术和临床上均有效,术中CBCT可作为透视的辅助工具,即时准确评估PARTO的技术成功。

研究设计与样本

  • 回顾性研究,纳入2016年1月至2016年12月接受PARTO的胃静脉曲张患者17例;术中于透视识别流入静脉近端后行非增强CBCT,不完全栓塞者追加明胶海绵注射;收集增强CT、上消化道内镜及临床和实验室随访数据。

关键影像表现/征象

  • CBCT显示15例胃静脉曲张完全栓塞,2例不完全栓塞。
  • 2例不完全栓塞者追加明胶海绵注射后,第2次CBCT示胃静脉曲张达完全栓塞。
  • PARTO后2-4个月随访CT示全部17例胃静脉曲张及门体分流明显缩小或完全闭塞。

诊断标准与关键数值

  • 术中非增强CBCT用于判断胃静脉曲张栓塞是否完全,不完全者追加明胶海绵。
  • PARTO技术成功定义为全部17例手术技术上成功。

临床应用与阅片要点

  • PARTO术中可行非增强CBCT确认胃静脉曲张栓塞是否完全。
  • CBCT示不完全栓塞时可追加明胶海绵注射并再次CBCT确认。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the technical and clinical outcomes of plug-assisted retrograde transvenous obliteration (PARTO) for the treatment of gastric varices (GV) and to evaluate the role of intra-procedural cone-beam computed tomography (CBCT) performed during PARTO to confirm its technical success.

MATERIALS AND METHODS: From January 2016 to December 2016, 17 patients with GV who had undergone PARTO were retrospectively evaluated. When the proximal part of the afferent vein was identified on a fluoroscopy, non-contrast CBCT images were obtained. In patients with incomplete embolization of GV, an additional injection of gelatin sponges was performed. Follow-up data from contrast-enhanced CT and upper intestinal endoscopy, as well as clinical and laboratory data were collected.

RESULTS: Plug-assisted retrograde transvenous obliteration procedures were technically successful in all 17 patients. Complete embolization of GV was detected on CBCT images in 15 patients; whereas, incomplete embolization was detected in two. Complete embolization of GV was then achieved after an additional injection of gelatin sponges in these two patients as demonstrated on the 2nd CBCT image. The mean follow-up period after PARTO was 193 days (range, 73-383 days). A follow-up CT obtained 2-4 months after PARTO demonstrated marked shrinkage or complete obliteration of GV and portosystemic shunts in all 17 patients. There were no cases of variceal bleeding during the follow-up.

CONCLUSION: Plug-assisted retrograde transvenous obliteration is technically and clinically effective for the treatment of GV. In addition, intra-procedural CBCT can be an adjunct tool to fluoroscopy, because it can provide an immediate and accurate evaluation of the technical success of PARTO.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Gwon DI, Ko GY, Kwon YB, et al. Plug-Assisted Retrograde Transvenous Obliteration for the Treatment of Gastric Varices: The Role of Intra-Procedural Cone-Beam Computed Tomography. Korean J Radiol. 2018. PMID: 29520179. doi:10.3348/kjr.2018.19.2.223

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。