术前恶性肝脏肿瘤检测:1.5 T下三维T2加权序列与T2加权自旋回波和单次激发T2的对比
前瞻性纳入2012至2015年疑似恶性肝脏肿瘤患者33例,比较3D-T2-SPACE与T2-TSE、T2-HASTE、DWI及3D-T1-VIBE对恶性肝脏肿瘤的检出敏感度。3D-T2加权序列敏感度79.8%高于T2-TSE的68.1%(P<0.001),但HCC亚组差异未达显著;T1-VIBE和DWI敏感度高于T2加权序列。
要点
- 3D-T2加权序列检出恶性肝脏肿瘤敏感度79.8%,高于T2-TSE的68.1%(P<0.001)。
- HCC亚组中3D-T2与T2-TSE敏感度差异未达统计学显著。
- T1-VIBE和DWI对恶性肝脏肿瘤的敏感度高于T2加权序列。
核心结论
- 与T2-TSE相比,3D-T2加权序列在恶性肝脏肿瘤检出上表现出很有前景的性能。
研究设计与样本
- 前瞻性研究,纳入2012至2015年本机构因疑似恶性肝脏肿瘤行MRI检查的患者33例,均行增强3D-T1加权、DWI、3D-T2-SPACE、T2-HASTE和T2-TSE序列,以随访、手术及组织病理分析为参考标准。
诊断标准与关键数值
- 3D-T2加权序列检出恶性肝脏肿瘤敏感度79.8%,T2-TSE为68.1%,两者差异P<0.001。
- HCC亚组中3D-T2加权序列与T2-TSE的敏感度差异未达统计学显著。
- T1加权VIBE和DWI对恶性肝脏肿瘤的敏感度高于T2加权序列。
- 3D-T2-SPACE序列的伪影显著少于T2-TSE。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the performances of three-dimensional (3D)-T2-weighted sequences compared to standard T2-weighted turbo spin echo (T2-TSE), T2-half-Fourier acquisition single-shot turbo spin-echo (T2-HASTE), diffusion weighted imaging (DWI) and 3D-T1-weighted VIBE sequences in the preoperative detection of malignant liver tumors.
METHODS: From 2012 to 2015, all patients of our institution undergoing magnetic resonance imaging (MRI) examination for suspected malignant liver tumors were prospectively included. Patients had contrast-enhanced 3D-T1-weighted, DWI, 3D-T2-SPACE, T2-HASTE and T2-TSE sequences. Imaging findings were compared with those obtained at follow-up, surgery and histopathological analysis. Sensitivities for the detection of malignant liver tumors were compared for each sequence using McNemar test. A subgroup analysis was conducted for HCCs. Image artifacts were analyzed and compared using Wilcoxon paired signed rank-test.
RESULTS: Thirty-three patients were included: 13 patients had 40 hepatocellular carcinomas (HCC) and 20 had 54 liver metastases. 3D-T2-weighted sequences had a higher sensitivity than T2-weighted TSE sequences for the detection of malignant liver tumors (79.8% versus 68.1%; P < 0.001). The difference did not reach significance for HCC. T1-weighted VIBE and DWI had a higher sensitivity than T2-weighted sequences. 3D-T2-weighted-SPACE sequences showed significantly less artifacts than T2-weitghted TSE.
CONCLUSION: 3D-T2-weighted sequences show very promising performances for the detection of liver malignant tumors compared to T2-weighted TSE sequences.