文献速递腹部技术与安全CT

CT结肠成像中结直肠肿块的体积纹理分析:良恶性病变鉴别及与人工阅片性能的比较

Volumetric Textural Analysis of Colorectal Masses at CT Colonography: Differentiating Benign versus Malignant Pathology and Comparison with Human Reader Performance.
PubMed 文献 · Acad Radiol · 2018-03-19

本研究对59例成人非增强CT结肠成像中63个病理证实的结直肠肿块(平均4.2 cm)应用定量体积纹理分析(VTA),并与3名有CTC经验阅片者的5分法评估比较。VTA鉴别良恶性的AUC为0.936、总体准确率85.5%,与人工阅片(AUC 0.917、准确率84.7%)无显著差异,敏感度83.6%低于人工91.7%(P=.034),特异度87.5%高于人工77.4%(P=.007)。

要点

  • VTA鉴别≥3 cm结直肠肿块良恶性的AUC达0.936,总体准确率与有经验阅片者无显著差异。
  • VTA敏感度83.6%低于人工阅片91.7%(P=.034),特异度87.5%高于人工77.4%(P=.007)。
  • 3名阅片者间组内相关系数0.76,提示一致性良好至优秀。

核心结论

  • VTA在CTC上鉴别≥3 cm结直肠肿块良恶性表现出优秀性能,与有经验的人工阅片相当且可能互补。

研究设计与样本

  • 对59例成人(平均年龄66.5岁,范围45.9-91.6岁)非增强CTC中63个病理证实的结直肠肿块(平均大小4.2 cm,范围3-8 cm)应用经验证的定量VTA方法,并与3名有CTC经验阅片者的5分法独立评估比较AUC与准确率。

诊断标准与关键数值

  • VTA最佳敏感度83.6%、特异度87.5%、AUC 0.936,总体准确率85.5%;人工阅片敏感度91.7%、特异度77.4%、AUC 0.917,总体准确率84.7%。

临床应用与阅片要点

  • VTA可用于CTC上≥3 cm结直肠肿块的良恶性鉴别,其总体准确率与有经验阅片者相当且可能互补。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To (1) apply a quantitative volumetric textural analysis (VTA) to colorectal masses at CT colonography (CTC) for the differentiation of malignant and benign lesions and to (2) compare VTA with human performance.

MATERIALS AND METHODS: A validated, quantitative VTA method was applied to 63 pathologically proven colorectal masses (mean size, 4.2 cm; range, 3-8 cm) at noncontrast CTC in 59 adults (mean age, 66.5 years; range, 45.9-91.6 years). Fifty-one percent (32/63) of the masses were invasive adenocarcinoma, and the remaining 49% (31/63) were large benign adenomas. Three readers with CTC experience independently assessed the likelihood of malignancy using a 5-point scale (1 = definitely benign, 2 = probably benign, 3 = indeterminate, 4 = probably malignant, 5 = definitely malignant). Areas under the curve (AUCs) and accuracy levels were compared.

RESULTS: VTA achieved optimal sensitivity of 83.6% vs 91.7% for human readers (P = .034), with specificities of 87.5% and 77.4%, respectively (P = .007). No significant difference in overall accuracy was seen between VTA and human readers (85.5% vs 84.7%, P = .753). The AUC for differentiating benign and malignant lesions was 0.936 for VTA and 0.917 for human readers. Intraclass correlation coefficient among the human readers was 0.76, indicating good to excellent agreement.

CONCLUSION: VTA demonstrates excellent performance for distinguishing benign from malignant colorectal masses (≥3 cm) at CTC, comparable yet potentially complementary to experienced human performance.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Pooler BD, Lubner MG, Theis JR, et al. Volumetric Textural Analysis of Colorectal Masses at CT Colonography: Differentiating Benign versus Malignant Pathology and Comparison with Human Reader Performance. Acad Radiol. 2018. PMID: 29566994. doi:10.1016/j.acra.2018.03.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。