文献速递腹部MR

结直肠癌离体MR成像:甲醛固定前后与组织病理学表现的对照研究

Ex vivo MR imaging of colorectal carcinoma before and after formalin fixation: correlation with histopathologic findings.
PubMed 文献 · Abdom Radiol (NY) · 2018-01-01

纳入45例连续患者(47个癌灶),对手术切除标本在切除后及甲醛固定24小时后行1.5T离体MR扫描,两位放射科医师独立评估T分期及浆膜下线性结构。两位阅片者固定前后T分期准确率分别为91.5%、87.2%和91.5%、85.1%;浆膜下线性结构在11.1%的T2肿瘤和100%的T3肿瘤中观察到。肿瘤与黏膜下层、浆膜下层的CNR在固定前后均显著低于后者,肿瘤和固有肌层的CNR在甲醛固定后降低。

要点

  • 浆膜下线性结构见于11.1%的T2肿瘤和100%的T3肿瘤,提示T3-4肿瘤。
  • 固定前后T分期准确率分别为91.5%、87.2%和91.5%、85.1%。
  • 肿瘤和固有肌层的CNR在甲醛固定后降低。

核心结论

  • 浆膜下线性结构代表伴有肿瘤浸润的纤维化,提示T3-4肿瘤;与肿瘤相比,黏膜下层和浆膜下层呈高信号,黏膜和固有肌层呈低信号;甲醛固定后肿瘤和固有肌层的CNR降低。

研究设计与样本

  • 研究纳入45例连续患者(47个癌灶),标本在切除后及甲醛固定24小时后于1.5T行两次MR扫描,两位放射科医师独立评估T分期及浆膜下线性结构,第三位放射科医师测量垂直肿瘤距离及黏膜、黏膜下层、固有肌层、浆膜下层和肿瘤的CNR,以组织病理学为参考标准。

关键影像表现/征象

  • 浆膜下线性结构在11.1%的T2肿瘤和100%的T3肿瘤中被两位阅片者观察到。
  • 与肿瘤相比,黏膜下层和浆膜下层呈高信号,黏膜和固有肌层呈低信号。
  • 肿瘤与黏膜下层、浆膜下层的CNR在固定前后均显著低于后者(p < 0.05)。

诊断标准与关键数值

  • 两位阅片者固定前T分期准确率分别为91.5%和87.2%,固定后分别为91.5%和85.1%。
  • MRI与组织病理学的垂直肿瘤距离在固定前后均相关性良好,固定前后测量误差在3 mm以内。
  • 肿瘤和固有肌层的CNR在甲醛固定后降低(p < 0.05)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: We aimed to assess and compare ex vivo MRI of resected colorectal carcinoma before and after formalin fixation.

METHODS: We enrolled 45 consecutive patients (47 carcinomas) who underwent colorectal carcinoma surgery. Specimens underwent two MR scans at 1.5 T (after resection and 24 h after formalin fixation). Two radiologists evaluated all MR images independently regarding T-staging and the subserosal linear architecture. T-stage accuracy and frequency of linear architecture were calculated. A third radiologist measured vertical tumor distance and contrast-to-noise ratio (CNR) of the mucosa, submucosa, muscularis propria, subserosa, and tumor.

RESULTS: T-stage accuracy compared to histopathology by the two readers was 91.5% and 87.2% before fixation and 91.5% and 85.1% after fixation, respectively. Linear architecture was observed in 11.1% of T2 tumors and 100% of T3 tumors by both readers. The vertical tumor distance between histopathological and MRI findings was well correlated before and after fixation. The measurement error of the vertical tumor distance between before and after fixation was within 3 mm. CNR of the tumor was significantly lower than those of the submucosa and subserosa before and after fixation (p < 0.05). CNRs of the tumor and muscularis propria were decreased after formalin fixation (p < 0.05).

CONCLUSIONS: Subserosal linear architecture represented fibrosis with tumoral invasion, suggesting a T3-4 tumor. The submucosa and subserosa showed high intensity and the mucosa and muscularis propria showed low intensity compared with tumor. CNRs of the tumor and muscularis propria were decreased by formalin fixation.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Inoue A, Ohta S, Nitta N, et al. Ex vivo MR imaging of colorectal carcinoma before and after formalin fixation: correlation with histopathologic findings. Abdom Radiol (NY). 2018. PMID: 29492606. doi:10.1007/s00261-018-1538-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。