文献速递心血管MR

心肌晚期钆增强:运动校正平衡稳态自由进动与分段涡轮快速小角度激发序列的头对头比较

Myocardial late gadolinium enhancement: a head-to-head comparison of motion-corrected balanced steady-state free precession with segmented turbo fast low angle shot.
PubMed 文献 · Clin Radiol · 2018-03-14

在59例连续心血管疾病患者中头对头比较运动校正平衡稳态自由进动PSIR与常规分段FLASH PSIR的LGE图像质量与诊断一致性;运动校正bSSFP的LGE信噪比、对比噪声比及总体图像质量更高,两种方法对LGE范围的定量一致性好且相关性高;运动校正bSSFP是可行的LGE序列,尤其适用于心律失常及因严重心力衰竭无法屏气的患者。

要点

  • 运动校正bSSFP的LGE信噪比53.6±35.6高于FLASH的27.7±18.5(p<0.001)。
  • 运动校正bSSFP总体图像质量中位数4高于FLASH中位数3(p<0.001)。
  • 两种方法定量LGE范围一致性好且相关性高(r=0.992,p<0.001)。

核心结论

  • 运动校正bSSFP是可行、稳健的LGE成像序列,尤其适用于心律失常及因严重心力衰竭无法屏气的患者。

研究设计与样本

  • 在59例连续心血管疾病患者中头对头比较运动校正bSSFP PSIR与常规分段FLASH PSIR的LGE图像质量与诊断一致性,比较正常心肌、LGE及血池的信噪比与对比噪声比,并用1–4级半定量评分比较总体图像质量,以透壁程度和LGE绝对定量范围评估诊断一致性。

关键影像表现/征象

  • 运动校正bSSFP的正常心肌、LGE及血池信噪比分别为4.8±3.4、53.6±35.6、43.2±29.3。
  • FLASH的正常心肌、LGE及血池信噪比分别为3.9±3.6(p=0.126)、27.7±18.5(p<0.001)、24.3±13.4(p<0.001)。
  • 运动校正bSSFP的LGE对正常心肌、LGE对血池、血池对正常心肌对比噪声比分别为48.3±33.1、6.5±21.6、38.3±27.2。
  • FLASH的LGE对正常心肌、LGE对血池、血池对正常心肌对比噪声比分别为23.8±16.7(p<0.001)、3.8±10.8(p<0.001)、20.3±10.7(p=0.448)。
  • 运动校正bSSFP总体图像质量中位数4高于分段FLASH中位数3(p<0.001)。

诊断标准与关键数值

  • 总体图像质量采用半定量评分系统(1–4级)评估,运动校正bSSFP中位数4 vs FLASH中位数3(p<0.001)。
  • 两种方法定量LGE范围一致性好且相关性高(r=0.992,p<0.001)。
  • 诊断一致性通过LGE透壁严重程度和绝对定量范围两方面评估。

临床应用与阅片要点

  • 运动校正bSSFP可作为LGE成像的可行序列,尤其适用于心律失常及因严重心力衰竭无法屏气的患者。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the image quality and diagnostic agreement with a head-to-head comparison of late gadolinium enhancement (LGE) images acquired by the motion-corrected (MOCO) balanced steady-state free precession (bSSFP) phase sensitivity inversion recovery (PSIR) and conventional segmented fast low angle shot (FLASH) PSIR methods15,16 in a patient cohort with a wide spectrum of cardiovascular disease.

MATERIALS AND METHODS: In 59 consecutive patients, signal-to-noise ratios (SNRs), contrast-to-noise ratios (CNRs) of the normal myocardium (NM), LGE, and blood pool (BP) were pair-wise compared between the two different sequences. A further semi-qualitative score system (graded 1 -4) was used to compare the overall image quality (OIQ). The diagnostic agreement of the two techniques were evaluated by both transmural severity and absolutely quantitative size of LGE.

RESULTS: The SNRs of the NM, LGE, and BP of MOCO bSSFP were 4.8±3.4, 53.6±35.6 and 43.2±29.3, compared with 3.9±3.6 (p=0.126), 27.7±18.5 (p<0.001) and 24.3±13.4 (p<0.001) of FLASH LGE, respectively. The CNRs of LGE to NM, LGE to BP, and BP to NM were 48.3±33.1 versus 23.8±16.7 (p<0.001), 6.5±21.6 versus 3.8±10.8 (p<0.001), and 38.3±27.2 versus 20.3±10.7 (p=0.448), respectively. The OIQ of MOCO bSSFP was higher than that of segmented FLASH (median 4 versus median 3, p<0.001). For quantification of LGE size, there is good agreement and high correlation (r=0.992, p<0.001) between the two methods.

CONCLUSIONS: MOCO bSSFP is a feasible, robust sequence for LGE imaging, especially for patients with arrhythmia and those incapable of breath-holding due to severe heart failure.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Fan H, Li S, Lu M, et al. Myocardial late gadolinium enhancement: a head-to-head comparison of motion-corrected balanced steady-state free precession with segmented turbo fast low angle shot. Clin Radiol. 2018. PMID: 29548551. doi:10.1016/j.crad.2018.02.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。