右心室收缩末期面积作为预测转诊心脏磁共振儿童右心室扩大及收缩功能减低的一线简易指标
研究分析60例儿童心脏磁共振检查,评估右心室四腔心收缩末期面积(4CH ESA)等简易参数与右心室舒张末期容积指数(RVEDVI)及射血分数(RVEF)的相关性。结果显示4CH ESA与RVEDVI相关性最佳(r=0.85),以8.5 cm²/m²为阈值预测右心室扩大AUC=0.912、敏感度92.3%、特异度79%;以10.5 cm²/m²为阈值预测右心室收缩功能减低AUC=0.873、敏感度83%、特异度89%。作者认为4CH ESA似乎是临床常规筛查中识别右心室功能障碍患者的可靠且简便的方法。
要点
- 4CH ESA与RVEDVI相关性最佳(r=0.85),优于4CH EDA(r=0.82)。
- 4CH ESA阈值8.5 cm²/m²预测右心室扩大:AUC=0.912,敏感度92.3%,特异度79%。
- 4CH ESA阈值10.5 cm²/m²预测右心室收缩功能减低:AUC=0.873,敏感度83%,特异度89%。
核心结论
- 在临床常规筛查中,4CH ESA似乎是识别右心室功能障碍患者的可靠且简便的方法。
研究设计与样本
- 研究分析60例儿童心脏磁共振检查,测量4CH EDA、4CH ESA、FAC、RVD1、TAPSE及RVOT prox,并与RVEDVI和RVEF进行相关性分析。
诊断标准与关键数值
- 4CH ESA阈值8.5 cm²/m²预测右心室扩大:AUC=0.912(p<0.001),敏感度92.3%,特异度79%;4CH ESA阈值10.5 cm²/m²预测右心室收缩功能减低:AUC=0.873(p<0.001),敏感度83%,特异度89%。
临床应用与阅片要点
- 作者认为4CH ESA似乎是临床常规筛查中识别右心室功能障碍患者的可靠且简便的方法。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To assess the accuracy of simple cardiovascular magnetic resonance imaging (CMR) parameters for first-line analysis of right ventricle (RV) dysfunction in children to identify those who require in-depth analysis and those in whom simple assessment is sufficient.
MATERIALS AND METHODS: Sixty paediatric CMR studies were analysed. The following CMR parameters were measured: RV end-diastolic and end-systolic area (4CH EDA and 4CH ESA), fractional area change (FAC), RV diameter in end-diastole (RVD1), tricuspid annular plane systolic excursion (TAPSE), and RV outflow tract diameter in end-diastole (RVOT prox). They were correlated with RV end-diastolic volume (RVEDVI) and RV ejection fraction (RVEF).
RESULTS: RVEDVI correlated best with 4CH ESA (r=0.85, <0.001) and EDA (r=0.82, <0.001). For RVEF only a moderate reverse correlation was found for 4CH ESA (-0.56, <0.001), 4CH EDA (-0.49, 0.001) and positive correlation for FAC (0.49, <0.001). There was no correlation between TAPSE and RVEF and only weak between RVD1 and RVEDVI. A 4CH ESA cut-off value of 8.5 cm2/m2 had a very high diagnostic accuracy for predicting an enlarged RV (AUC=0.912, p<0.001, sensitivity 92.3%, specificity 79%) and a cut-off value of 10.5 cm2/m2 was also a good predictor of depressed RV systolic function (AUC=0.873, p<0.001, sensitivity 83%, specificity 89%).
CONCLUSION: For routine screening in clinical practice, 4CH ESA seems a reliable and easy method to identify patients with RV dysfunction.
引用
- Barczuk-Falęcka M, Małek ŁA, Roik D, et al. Right ventricular end-systolic area as a simple first-line marker predicting right ventricular enlargement and decreased systolic function in children referred for cardiac magnetic resonance imaging. Clin Radiol. 2018. PMID: 29519499. doi:10.1016/j.crad.2018.01.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。